ACCULINK 316x DSU/CSU

The bottom of the screen shows the addition of the Edit and Save functions.

The Save To: field can be populated with Active or Cust to enable a 1-step copy of one configuration option set into another when the Save function is subsequently selected. The default configuration option set is Active except if Load From: is set to Cust; then Cust is the default.

To edit the configuration options, select Edit. This displays the configuration menu shown in Figure 3-15.

The async terminal supports character matching for entering valid values in fields when editing configuration options. For example, the valid values for the main/configuration screen is Activ, Cust, Fact1, and Fact2. If you enter the character `C', the field automatically populates with the value that matches the character criteria. In this case, it would be Cust. Appendix C provides all the valid values available for each configuration option. Also refer to the section Using the Async Terminal Feature for a discussion of the edit screens.

Saving Edit Changes

Save edit changes to the Active area when you want those changes to take effect immediately. Save edit changes to the Customer area when you want to overwrite the existing Customer configuration options and store these changes for future use.

To save edit changes,

NOTE

If you attempt to exit the Edit function after making changes without performing a Save, the DSU/CSU prompts you with Save Options? Choose Yes or No.

1.From the Choose Function screen (one level above the Edit screen, two levels below the top-level menu screen), press F2 to select Save.

Choose Funct:

Edit Save

F1 F2 F3

2.Press F1 or F2 to choose whether you want to save to the Active or Customer area.

Save Edit to:

Activ Cust

F1 F2 F3

Differences Using the Async Terminal: All subsequent edit screens off the main/configuration menu on the async terminal provide the Save and Edit functions. When all edit changes are completed, select Save from the last screen. It returns you to the main/configuration/load screen as shown in Figure 3-17. Populate the Save To field on the main/configuration/load screen and select Save.