ACCULINK 316x DSU/CSU

Near End Group ± ªdsx1SendCodeº Object (dsx1ConfigEntry 7)

This object specifies the test patterns/codes being sent over the Network T1 interface. These tests are not supported on the DTE Drop/Insert T1 Interface. Only the following values are supported by the DSU/CSU.

dsx1SendNoCode(1) ± Specifies that the interface is sending normal or looped data. Setting the interface to this value stops an active ªsend patternº test on the interface. This is the only value supported by the DTE Drop/Insert T1 interface.

dsx1SendLineCode(2) ± Specifies that the Network T1 interface is sending a Remote Loopback (Rlpbk) LLBUP code. The code is sent for 10 seconds.

dsx1SendResetCode(4) ± Specifies that the Network T1 interface is sending Remote Loopback (Rlpbk) LLBDN code. The code is sent for 10 seconds.

dsx1SendQRS(5) ± Specifies that the Network T1 interface is sending a QRSS test pattern. The pattern is sent until the test is halted (i.e., setting to dsx1SendNoCode).

dsx1SendOtherTestPattern(8) ± Specifies that the Network T1 interface is sending a 1-in-8 test pattern. The pattern is sent until the test is halted (i.e., setting to dsx1SendNoCode).

Near End Group ± ªdsx1CircuitIdentifierº Object (dsx1ConfigEntry 8)

This object is not supported by the DSU/CSU.

Near End Group ± ªdsx1LoopbackConfigº Object (dsx1ConfigEntry 9)

This object specifies the loopback state of the T1 interfaces. Only the following values are supported by the DSU/CSU.

dsx1NoLoop(1) ± The T1 interface is not in a loopback state.

dsx1PayloadLoop(2) ± Specifies that a Payload Loopback (PLB) is active for the Network T1 interface or a Repeater Loopback (RLB) is active for the DTE Drop/Insert T1 interface.

dsx1LineLoop(3) ± Specifies that a Line Loopback (LLB) is active for the Network T1 interface or a DTE Loopback (DLB) is active for the DTE Drop/Insert T1 interface.

Near End Group ± ªdsx1LineStatusº Object (dsx1ConfigEntry 10)

This object specifies the line (alarm) status of the T1 interfaces. Only the following values are supported by the DSU/CSU. More than one value may be active at a time.

dsx1NoAlarm(1) ± No alarm present.

dsx1RcvFarEndLOF(2) ± A yellow alarm signal is being received.

dsx1RcvAIS(8) ± An Alarm Indication Signal (AIS) is being received.

dsx1LossOfFrame(32) ± An Out Of Frame condition has persisted for more that 2.5 seconds (i.e., Red Alarm).

dsx1LossOfSignal(64) ± A Loss of Signal condition has persisted for more that 2.5 seconds (i.e., Red Alarm).

dsx1LoopbackState(128) ± The near end of the T1 interfaces is in a loopback state.

dsx1Other Failure(4096) ± An Excessive Error Rate (EER) has been detected on the Network T1 interface.

Near End Group ± ªdsx1SignalModeº Object (dsx1ConfigEntry 11)

This object specifies whether Robbed Bit Signaling (RBS) is being used. This object differs from the MIB definition in that it is ªread-onlyº (not read/write) for DSU/CSUs. Only the following values are supported by the DSU/CSU.

none(1) ± No signaling is being used on this interface.

robbedBit(2) ± Robbed Bit Signaling is being used on at least one DS0 on this T1 interface.

E-8

December 1996

3160-A2-GB22-10

Page 188
Image 188