Enabling/Disabling the Front Panel

Installation

Enabling/Disabling the Front Panel

You can enable or disable the display of data through the front panel. This feature is useful for ensuring that other users do not inadvertently change the device's configuration options while you are using the PC or async terminal interface. The factory default is enable.

NOTE

If you disable the front panel, be sure not to alter the options for using the PC or Async terminal interface. If this happens, you lose the ability to communicate with the device. You will need to contact your service representative.

To enable or disable the front panel:

1.Press F3 to select Cnfig from the top-level menu screen.

DSU ESF

Stat Test Cnfig

F1 F2 F3

2.Select the configuration option set to be copied into the Edit area by using the appropriate function key. Use the scroll keys, if necessary.

Load from:

 

Activ

Cust

Fact1

F1

F2

F3

3. Press F1 to select Edit.

Choose Funct:

Edit Save

F1 F2 F3

4.Press the Manual background key from the Edit screen to display the User selection.

Edit:

DTE Port NET

F1 F2 F3

5. Press F3 to select User.

Edit:

Chan Gen User

F1 F2 F3

6.Press the F1 (Next) key until the front panel access configuration option appears.

Self-Test:Enab

Next Enab Disab

F1 F2 F3

7.Press F2 to enable the front panel or F3 to disable the front panel.

FP Access:

Next Enab Disab

F1 F2 F3