Health and Status Messages

ACCULINK 316x DSU/CSU

 

Table 3-9

 

Health and Status Messages

 

 

Message

Description

 

 

LOS at Net

A Loss Of Signal (LOS) condition (declared after 175 consecutive zeros) has been detected on

 

the network interface. The condition is cleared when the density of ones to zeros received is

 

12.5%.

 

 

LOS at DTE

An LOS condition (declared after 175 consecutive zeros) has been detected on the DSX-1

 

interface. The condition is cleared when the density of ones to zeros received is 12.5%.

 

 

OOF at Net

An Out Of Frame (OOF) condition (2 out of 4 frame synchronization bits in error) has been

 

detected on the network interface. The condition is cleared when a reframe occurs.

 

 

OOF at DTE

An Out Of Frame has been detected on the DSX-1 interface. The condition is cleared when a

 

reframe occurs.

 

 

AIS at Net

An Alarm Indication Signal (unframed all ones signal) is being received by the network interface.

 

 

AIS at DTE

An Alarm Indication Signal is being received by the DSX-1 interface.

 

 

EER at Net

The error rate of the received network signal exceeds the currently configured threshold (if the

 

network is configured for ESF framing). The condition is cleared when the error rate falls below

 

the threshold value.

 

 

Yellow at Net

A yellow alarm signal is being received by the network interface.

 

 

Yellow at DTE

A yellow alarm signal is being received by the DSX-1 interface.

 

 

Selftest failed

A failure was detected during the power-on self-test. Select STest under the Stat branch to

 

display more information about the failure.

 

 

DevFail ########

An internal error has been detected by the operating software. An 8-digit code appears for use

 

by service personnel. The condition is cleared by resetting the device.

 

 

Download failed

A download attempt was interrupted and failed to complete. The condition is cleared by resetting

 

the device.

 

 

Alrm Retry Disab

Appears only if an alarm message attempts to exceed the maximum number of alarm retries.

 

 

Test in progress

A test is currently active. Select Tstat under the Stat branch to display more information about

 

the test.

 

 

Modem Connected

The integral modem is currently connected. This message is only displayed for 3160/3164

 

DSU/CSUs.

 

 

Master Clk fail

The master clock has failed. Timing for the DSU/CSU is provided by the internal clock.

 

 

SNMP Link Down

The currently configured SNMP management link is down, allowing no communication between

 

the management system and the device. If the management link is configured on the MODEM

 

port, the modem must be currently connected for this message to display.

 

 