ACCULINK 316x DSU/CSU

8.Press F2 (Edit) to edit the IP address. You have the option of using F3 (Clear) to reset the IP address to the factory default 000.000.000.000. Refer to the Setting the IP Address section earlier in this chapter for more information on setting an IP address.

Trap n IP Adr:

Next Edit Clear

F1 F2 F3

Differences Using the Async Terminal: To set the IP address for the SNMP Trap Manager, select Trap Options from the main/configuration/edit/snmp menu. (See Figure 3-23 for an example of the screen that appears.)

Configuring DS0 Channels

The 316x DSU/CSU provides channel configuration options that allow you to do the following:

Display the DS0 assignments for the Network and DSX-1 Drop/Insert T1 interfaces.

Allocate DS0 channels on the DSX-1 Drop/Insert T1 interface to the Network interface.

Allocate DS0 channels on the Network or DSX-1 Drop/Insert T1 interfaces to particular data ports.

Clear (deallocate) all DS0 channels from the Network or DSX-1 Drop/Insert T1 interfaces.

To allocate DS0 channels, begin by defining logical

channel configuration for Network interface, and then the DTE Drop/Insert interface, and then any ports, if desired. See Figure 3-24 for an example of a conceptual diagram of channel configuration.

To complete the configuration worksheets for DS0 channel allocation:

1.Complete the Network T1 Interface and the DSX-1 Drop/Insert Interface tables (unless the DSX-1 Drop/Insert interface is disabled) as shown in Figure 3-25. Figure 3-26 contains a worksheet for specifying which DS0 channels carry Robbed Bit Signaling (RBS) information for voice channels. Figures 3-27 and 3-28 contain a worksheet for allocating data ports.

2.Using the worksheets provided in Appendix G, circle the configuration options needed to implement the logical channel configuration.

Once you have completed the worksheets, enter this information using the front panel of the DSU/CSU or the Async terminal interface. Procedures are listed later in this section; configuration options are listed in Appendix C. For additional worksheets, see Appendix G.

Differences Using the Async Terminal: Menu organization for the async terminal makes the selections for configuring and displaying channels slightly different from the front panel. To edit or display channel configurations, select Channel from the main/configuration/edit menu.

The channel menu provides the selection Display Channels which combines the NET and DTE selections found under the Dsply selection on the front panel.

Clear NET, Clear DTE, DTE Assign, and DTE Voice are all individual selections at the channel menu level. The front panel has these selections subleveled with DTE and NET under Clear and Assign and Voice under DTE. The channel menu also provides individual port selections. (See Figures 3-14 and 3-15 for menu hierarchy differences between interfaces.)

3-34

December 1996

3160-A2-GB22-10

Page 76
Image 76
Paradyne 316x manual Configuring DS0 Channels, Trap n IP Adr Next Edit Clear