Paradyne 316x manual Interface Group ± ªifAdminStatusº Object ifEntry

Models: 316x

1 211
Download 211 pages 11.69 Kb
Page 185
Image 185
Interface Group ± ªifAdminStatusº Object (ifEntry 7)

SNMP MIB Objects

Interface Group ± ªifAdminStatusº Object (ifEntry 7)

This object specifies the desired state (configuration) of the interface. This object is supported only for the MODEM port. It provides the ability to switch between using the MODEM port as the SNMP management link and ASCII operations (Dial-out, FPE). Refer to the 3100 Series device document for more information. The value of this object will not affect the state of any of the interfaces on the T1 DSU/CSU other than the MODEM port. Only the following values are supported by the DSU/CSU:

up(1) ± The SNMP management link is active on the MODEM port (i.e., the Modem Use configuration option is set to SNMP).

testing(3) ± The SNMP management link is inactive on the MODEM port and can be used for proprietary ASCII functions.

Interface Group ± ªifOperStatusº Object (ifEntry 8)

This object specifies the current operational state of the interface. The value of this object for each interface is defined as follows:

Network T1:

The interface is up(1) when no

 

alarm conditions exist.

 

The interface is down(2) when an

 

alarm condition is active.

DTE

The interface is up(1) when no

Drop/Insert T1:

alarm conditions exist and the I/F

 

is enabled.

 

The interface is down(2) when an

 

alarm condition is active and the

 

I/F is disabled.

 

The interface is testing(3) when a

 

test is active on the interface.

COM Port:

When configured as the SNMP

 

management link, up and down are

 

based on the current state of the

 

link layer protocol. Otherwise, the

 

interface is always up(1).

 

The interface is never in the

 

testing(3) state.

MODEM Port:

When configured as the SNMP

 

management link, up and down are

 

based on the current state of the

 

link layer protocol. Otherwise, the

 

interface is always up(1) when the

 

MODEM is connected and

 

down(2) when the MODEM is not

 

connected.

 

The interface is never in the

 

testing(3) state.

Data Ports:

The interface is up(1) when the

 

port is assigned to a T1 interface

 

and both CTS and DSR are ON.

 

The interface is down(2) when the

 

port is unassigned or either CTS or

 

DSR is OFF.

 

The interface is testing(3) when a

 

test is active on the interface.

Interface Group ± Input Counters (objects ifEntry 10 to ifEntry 15)

The objects used to collect statistics on the data received by an interface apply only to the COM port and the MODEM port when the port is configured as the SNMP management link. For interfaces that are not configured as the SNMP management link, these statistics are not provided and an error status is returned if access is attempted. The objects used to collect input statistics are listed below:

ifInOctets (ifEntry 10)

ifInUcastPkts (ifEntry 11)

ifInNUcastPkts (ifEntry 12)

ifInDiscards (ifEntry 13)

ifInErrors (ifEntry 14)

ifInUnknownProtos (ifEntry 15)

3160-A2-GB22-10

December 1996

E-5

Page 185
Image 185
Paradyne 316x manual Interface Group ± ªifAdminStatusº Object ifEntry