Paradyne 316x Number of Ports ± ªrs232Numberº Object rs232, General Port Table, RS-232-like MIB

Models: 316x

1 211
Download 211 pages 11.69 Kb
Page 191
Image 191
Number of Ports ± ªrs232Numberº Object (rs232 1)

SNMP MIB Objects

Number of Ports ± ªrs232Numberº Object (rs232 1)

This object contains the number of ports in the RS-232-like general port table. This number is 4 for the 3160 DSU/CSU and 6 for the 3164 DSU/CSU.

General Port Table, RS-232-like MIB

The general port table contains general configuration objects for the RS-232-like interfaces.

General Port Table ± ªrs232PortIndexº Object (rs232PortEntry 1)

This object contains a unique value for each port and is used as an index into the general port table (rs232PortTable).

General Port Table ± ªrs232PortOutSigNumberº Object (rs232PortEntry 4)

This object contains the number of output signals contained in the output signal table. This is the number of signals that can be asserted. This number is 2 for the synchronous DCE ports and 0 for the MODEM and COM ports.

General Port Table ± ªrs232PortInSpeedº Object (rs232PortEntry 5)

This object contains the port's input speed in bits per second. For the T1 DSU/CSU, this object is read-only. The input speed of a synchronous data port is determined by the channel configuration and cannot be changed through this object. The input speed of the MODEM or COM port is the currently configured speed.

General Port Table ± ªrs232PortTypeº Object (rs232PortEntry 2)

This object is used to identify the ports hardware type. Only the following values are supported by the DSU/CSU.

rs232(2) ± Used to identify the MODEM and COM ports.

rs422(3) ± Used to identify ports that are configured as EIA-530A or RS-449.

V35(5) ± Used to identify ports that are configured as V.35.

General Port Table ± ªrs232PortInSigNumberº Object (rs232PortEntry 3)

This object contains the number of input signals contained in the input signal table. This is the number of signals that can be detected. This number is 2 for the synchronous DCE ports and 0 for the MODEM and COM ports.

General Port Table ± ªrs232PortOutSpeedº Object (rs232PortEntry 6)

This object contains the port's output speed in bits per second. For the T1 DSU/CSU this object will be read-only. The output speed of a synchronous data port is determined by the channel configuration and cannot be changed through this object. The output speed of the MODEM or COM port is the currently configured speed.

Asynchronous Port Table, RS-232-like MIB

The asynchronous port table contains an entry for each of the MODEM or COM port when the port is configured for asynchronous operation. For the T1 DSU/CSU, the entries in the table that are counters (rs232AsyncPortEntry 6±8) are used to collect statistics and are not supported.

Asynchronous Port Table, ªrs232AsyncPortBitsº (rs232AsyncPortEntry 2)

This object specifies the number of bits in a character. Only the following values are supported by the DSU/CSU.

7 ± 7-bit characters.

8 ± 8-bit characters.

3160-A2-GB22-10

December 1996

E-11

Page 191
Image 191
Paradyne 316x manual Number of Ports ± ªrs232Numberº Object rs232, General Port Table, RS-232-like MIB