ACCULINK 316x DSU/CSU

Installing the Redundant ±￿48 Vdc Power

Supply

To install the 3160/3164 DSU/CSU using a redundant

±48 Vdc power supply, refer to Figure 2-9 and use the following procedure.

To install the redundant ±48 Vdc power supply,

1.Connect the black wire to the ±48 Vdc return source B.

2.Connect the red wire to the ±48 Vdc return source A.

3.Connect the green wire to a suitable earth ground.

4.Connect the orange wire to the ±48 Vdc input source B.

5.Connect the blue wire to the ±48 Vdc input source A.

6.Cut the white wire off at the outer insulation.

7.Plug the power connector into the 3160/3164 DSU/CSU.

Figure 2-9. ±￿48 Vdc Redundant Source Power Supply Pinouts

2-8

December 1996

3160-A2-GB22-10

Page 31
Image 31
Paradyne 316x manual Installing the Redundant ±48 Vdc Power Supply, ±48 Vdc Redundant Source Power Supply Pinouts