Paradyne 316x manual Table C-10 1 of SNMP Trap Configuration Options

Models: 316x

1 211
Download 211 pages 11.69 Kb
Page 163
Image 163
Table C-10

ACCULINK 316x DSU/CSU

Table C-10

(1 of 2)

SNMP Trap Configuration Options

Num Trap Mgrs: 1

Next 1 2 3 4 5 6 Prev

Number of Trap Managers. Specifies the number of trap managers supported by the unit.

NOTE: You must configure an IP address for each trap manager that is to receive trap messages.

Trap n IP Adr: Clear

Next Edit Clear Prev

Trap n IP Address. Specifies the IP address for each trap manager. This configuration option is repeated for all trap managers supported by the unit.

Edit ± Allows you to edit or display the IP address for Trap Manager n using the generic IP address data entry screen.

Clear ± Allows you to clear the IP address for Trap Manager n.

Gen Trap: Both

Next Disab Warm Auth Both Prev

General Trap Types. Specifies the general trap types to enable.

Disab ± Disables the sending of trap messages for warmStart and authenticationFailure events to the currently configured trap manager(s).

Warm ± Sends trap messages for warmStart events to the currently configured trap manager(s). A warmStart trap signifies the unit has reinitialized itself. This trap is sent after the unit resets and stabilizes.

Auth ± Sends trap messages for authenticationFailure events to the currently configured trap manager(s). An authenticationFailure trap signifies that the unit is the addressee of an SNMP protocol message that is not properly authenticated.

Both ± Sends trap messages for warmStart and authenticationFailure events to the currently configured trap manager(s).

NOTE: This configuration option is not available and is not displayed if the SNMP Trap alarm configuration option is disabled.

Entp Trap: Enab

Next Enab Disab Prev

Enterprise Specific Traps. Specifies whether the enterpriseSpecific trap is enabled. An enterpriseSpecific trap signifies the unit has recognized an enterprise specific event. The Specific Trap field identifies the particular trap that has occurred. These traps generate because of the following events:

enterpriseSelfTestFail(2) ± A hardware failure of the unit was detected as part of the unit's self-test. This is gener- ated after the unit has completed initialization.

enterpriseDeviceFail(3) ± An internal device failure was detected by the operating software for the unit.

Disab ± Disables the sending of trap messages for enterpriseSpecific events to the currently configured trap manager(s).

Enab ± Sends trap messages for enterpriseSpecific events to the currently configured trap manager(s).

NOTE: This configuration option is not available and is not displayed if the SNMP Trap alarm configuration option is disabled.