ACCULINK 316x DSU/CSU

 

Table 3-10

 

Self-Test Health Messages

 

 

Message

Description

 

 

Passed

No problems found during power-up.

 

 

CPU fail

Central Processing Unit failed internal testing.

 

 

DTE T1 fail

Unit failed to internally loop data on the DTE circuit.

 

 

Failure xxxxxxxx

An 8-digit hexadecimal failure code provided for service personnel.

 

 

LCD fail

The front panel Liquid Crystal Display (LCD) failed.

 

 

Memory fail

Unit failed program checksum verification.

 

 

Modem fail

Unit failed to internally loop data through the modem circuit.

 

 

NET T1 fail

Unit failed to internally loop data on the network circuit.

 

 

Device fail

One or more of the unit's integrated circuit chips failed to pass internal device level testing.

 

 

B8ZS/LOS fail

Unit failed to encode data properly or to detect Loss Of Signal.

 

 

Alarm fail

Unit failed to transmit AIS or to detect Yellow alarm.

 

 

DSU fail

Unit failed to internally loop data on the DSU.

 

 

DSU Portn fail

Port's integrated circuit failed to pass device internal testing.

 

 

Unknown Exp Dev

Unit unable to recognize the expansion device connected to the main circuit board.

 

 

Displaying Self-Test Results

To display power-up self-test results,

1.Press F1 to select Stat from the top-level menu screen.

DSU ESF

Stat Test Cnfig

F1 F2 F3

2. From the Status screen, press F2 to select STest.

Status:

DevHS STest Perf

3.View the results of the last power-up self-test. If no problems were found during power-up, the following message appears.

STest Health:

Passed

F1 F2 F3

F1 F2 F3

3-56

December 1996

3160-A2-GB22-10