Optional Power Selection

ACCULINK 316x DSU/CSU

5.If you intend to manage the 3160/3164 DSU/CSU with SNMP, cable either the COM or MODEM port (as appropriate for your configuration). Then, configure the SNMP management link. See Chapter 3, Operation, and Appendix C, Configuration Options, for more information.

6.If you do not intend to use the DTE Drop/Insert T1 port, disable it using the configuration procedures in Chapter 3, Operation, and Appendix C, Configuration Options. (The default setting for this port is Enabled.)

7.The Factory 1 configuration for ESF framing format and B8ZS line coding format is the default configuration and is appropriate for most networks. If this configuration does not work for you, try the Factory 2 configuration for D4 framing format and AMI line coding format. To further customize configuration options, refer to the Configuring the DSU/CSU section in Chapter 3, Operation, and to Appendix C, Configuration Options.

8.Verify that the DSU/CSU is functional by observing that the OK and NETWORK SIG LEDs are lit.

9.Configure the ports and channels you intend to use and assign channels to the network interface. To do so, refer to Configuring the DSU/CSU section

in Chapter 3, Operation, and to Appendix C, Configuration Options.

Optional Power Selection

Using the optional dc power cable, the 3160/3164 DSU/CSU is capable of operating on either a +24 Vdc power source, ± 48 Vdc single source battery, or ± 48 Vdc redundant source batteries (for power backup). To select the power, choose one of the following power supply types.

Installing the +24 Vdc Power Supply

To install the 3160/3164 DSU/CSU using a +24 Vdc power supply, refer to Figure 2-7 and use the following procedure.

To install the +24 Vdc power supply,

1.Connect the green wire to a suitable earth ground.

2.Connect the white wire to the +24 Vdc return.

3.Connect the orange wire to the +24 Vdc source.

4.Cut the black, red and blue wires off at the outer insulation.

5.Plug the power connector into the 3160/3164 DSU/CSU.

Figure 2-7. +24 Vdc Power Supply Pinouts