Paradyne 316x manual Table C-9 1 of General SNMP Configuration Options

Models: 316x

1 211
Download 211 pages 11.69 Kb
Page 161
Image 161
SNMP Configuration Options

ACCULINK 316x DSU/CSU

SNMP Configuration Options

The SNMP configuration options are divided into two tables as follows:

General SNMP Configuration Options (Table C-9)

SNMP Trap Configuration Options (Table C-10)

Table C-9

(1 of 2)

General SNMP Configuration Options

System Name: Clear

Next Edit Clear Prev

System Name. Specifies the SNMP system name for this unit. This is the node's fully qualified domain name.

Edit ± Allows you to edit or display the system name using the generic text string entry screen.

Clear ± Allows you to clear the system name.

System Location: Clear

Next Edit Clear Prev

System Location. Specifies the SNMP system location for this unit. This is the physical location of this SNMP-managed node.

Edit ± Allows you to edit or display the system location using the generic text string entry screen.

Clear ± Allows you to clear the system location.

System Contact: Clear

Next Edit Clear Prev

System Contact. Specifies the SNMP system contact person for this unit, and how to contact this person.

Edit ± Allows you to edit or display the system contact using the generic text string entry screen.

Clear ± Allows you to clear the system contact.

CommunityName1: Edit

Next Edit Clear Prev

Community Name 1. Specifies the first of two community names allowed access to this unit's Management Information Base (MIB). External SNMP managers must supply this name to access an object in the MIB.

Edit ± Allows you to edit or display the first community name using the generic text string entry screen.

Clear ± Allows you to clear the first community name.

Access 1: Read

Next Read R/W Prev

Access 1. Specifies the type of access allowed for community name 1. This is the type of access allowed for external SNMP managers accessing objects in the MIB using community name 1.

Read ± Allows read-only access (SNMP Get) to the accessible objects in the MIB for this device when community name 1 is used. This includes all objects specified as either read-only or read/write in the MIB RFCs.

R/W ± Allows read and write access (SNMP Get and Set) to the objects in the MIB for this device when community name 1 is used. Write access is allowed for all objects specified as read/write in the MIB RFCs. Read access is allowed for all objects specified as either read-only or read/write.

CommunityName2: Edit

Next Edit Clear Prev

Community Name 2. Specifies the second of two community names allowed access to this unit's Management Information Base (MIB). External SNMP managers must supply this name to access an object in the MIB.

Edit ± Allows you to edit or display the second community name using the generic text string entry screen.

Clear ± Allows you to clear the second community name.

C-20

December 1996

3160-A2-GB22-10

Page 161
Image 161
Paradyne 316x manual Table C-9 1 of General SNMP Configuration Options, System Name Clear Next Edit Clear Prev