testMonQRSS ± Initiates a Monitor QRSS test on the interface. Supported for the data ports and the Network T1 interface.

testMon511 ± Initiates a Monitor 511 test on the interface. Only supported for the data ports.

testSendQRSS ± Initiates a Send QRSS test on the interface. Only supported for the data ports.

testSend511 ± Initiates a send 511 test on the interface. Only supported for the data ports.

testSendV54Up ± Sends a V54 up code to the remote unit. Only supported for the data ports.

testSendV54Down ±Sends a V54 down code to the remote unit. Only supported for the data ports.

testSendFT1Up ± ends a FT1 up code to the remote unit. Only supported for the data ports.

testSendFT1Down ± Sends a FT1 down code to the remote unit. Only supported for the data ports.

Where these object identifiers are defined as follows:

testLoopDTLB ± OBJECT IDENTIFIER ::= [wellKnownTests 2]

testMonQRSS ± OBJECT IDENTIFIER ::= [wellKnownTests 3]

testMon511 ± OBJECT IDENTIFIER ::= [wellKnownTests 4]

testSendQRSS ± OBJECT IDENTIFIER ::= [wellKnownTests 5]

testSend511 ± OBJECT IDENTIFIER ::= [wellKnownTests 6]

testSendV54Up ± OBJECT IDENTIFIER ::= [wellKnownTests 7]

testSendV54Down ± OBJECT IDENTIFIER ::= [wellKnownTests 8]

testSendFT1Up ± OBJECT IDENTIFIER ::= [wellKnownTests 9]

testSendFT1Down ± OBJECT IDENTIFIER ::= [wellKnownTests 10]

Generic Interface Test Table ± ªifExtnsTestResultº Object (ifExtnsTestEntry 5)

This object contains the result of the most recently requested test. Only the following values are supported by the DSU/CSU.

none(1) ± No test currently active.

inProgress(3) ± A test is currently in progress.

notSupported(4) ± The requested test is not supported.

unAbleToRun(5) ± The requested test cannot run due to the state of the unit.

Generic Interface Test Table ± ªifExtnsTestCodeº Object (ifExtnsTestEntry 6)

This object contains a code which contains more specific information on the test result. This object is defined as an INTEGER. Only the following values are supported by the DSU/CSU.

none ± No further information is available. Used for the send pattern/code and loopback tests.

inSyncNoBitErrors ± A monitor pattern (QRSS or

511)test has synchronized on the pattern and has not detected any bit errors.

inSyncWithBitErrors ± A monitor pattern (QRSS or

511)test has synchronized on the pattern and has detected bit errors.

notInSync ± A monitor pattern (QRSS or 511) test has not synchronized on the requested pattern.

Where these object identifiers are defined as follows:

wellKnownCodes ± OBJECT IDENTIFIER ::= [ifExtensions 5]

none ± OBJECT IDENTIFIER ::= [wellKnownCodes 1]

inSyncNoBitErrors ± OBJECT IDENTIFIER ::= [wellKnownCodes 2]

inSyncWithBitErrors ± OBJECT IDENTIFIER ::= [wellKnownCodes 3]

notInSync ± OBJECT IDENTIFIER ::= [wellKnownCodes 4]