Paradyne 316x manual DSX-1 Drop/Insert Port LEDs, Name, Color, Meaning, Alrm

Models: 316x

1 211
Download 211 pages 11.69 Kb
Page 51
Image 51
DSX-1 Drop/Insert Port LEDs

Operation

 

 

 

Table 3-3

 

 

 

DSX-1 Drop/Insert Port LEDs

 

 

 

 

Name

Color

 

Meaning

 

 

 

SIG

Green

Monitors the signal being received from the DSX-1.

 

 

ON:

A recoverable signal is being received from the DSX-1.

 

 

OFF:

The signal cannot be recovered from the DSX-1 (a Loss of Signal

 

 

 

condition exists).

 

 

 

OOF

Yellow

Monitors Out Of Frame (OOF) conditions on the received DSX-1 signal.

 

 

ON:

At least one OOF was detected on the signal during the sampling

 

 

 

period.

 

 

OFF:

No OOFs were detected on the signal during the sampling period.

 

 

 

ALRM

Yellow

Indicates whether an alarm condition exists on the received DSX-1 signal.

 

 

ON:

An alarm condition (LOS, LOF, EER, Yellow, AIS) exists on the received

 

 

 

DSX-1 signal. Use the Device Health and Status command to determine

 

 

 

the alarm type.

 

 

OFF:

No alarm condition exists on the DSX-1 Interface signal.

 

 

 

PDV

Yellow

Monitors Pulse Density Violations (PDV) on the received DSX-1 signal.

 

 

ON :

At least one PDV was detected (and corrected) on the received DSX-1

 

 

 

signal during the sampling period.

 

 

OFF:

No PDVs were detected on the received DSX-1 signal during the

 

 

 

sampling period.

 

 

 

BPV

Yellow

Monitors DSX-1 Bipolar Violations (BPV) on the received DSX-1 signal.

 

 

ON:

At least one BPV was detected (and corrected) on the received DSX-1

 

 

 

signal during the sampling period.

 

 

OFF:

No BPVs were detected on the received DSX-1 signal during the

 

 

 

sampling period.

 

 

 

 

3160-A2-GB22-10

December 1996

3-9

Page 51
Image 51
Paradyne 316x manual DSX-1 Drop/Insert Port LEDs, Name, Color, Meaning, Alrm