Selecting the Number of Trap Managers

ACCULINK 316x DSU/CSU

Selecting the Number of Trap Managers

If you intend to issue traps to an SNMP manager(s) from this device, you must specify the number of SNMP managers that are to receive the traps.

To specify the number of SNMP managers to receive traps from this device,

1.Press F3 to select Cnfig from the top-level menu screen.

DSU ESF

Stat Test Cnfig

F1 F2 F3

2.Select the configuration option set to be copied into the Edit area by using the appropriate function key. Use the scroll keys, if necessary.

Load from:

 

Activ

Cust

Fact1

F1

F2

F3

3. Press F1 to select Edit.

Choose Funct:

Edit Save

F1 F2 F3

4.Press the Manual background key from the Edit screen to display the SNMP selection.

Edit:

DTE Port NET

F1 F2 F3

5. Press F3 to select SNMP.

Edit:

 

 

User

Alarm

SNMP

F1

F2

F3

6.Press F2 to select Trap from the SNMP Config screen.

SNMP Config:

Gen Trap

F1 F2 F3

7.Select the number of SNMP managers to receive traps (from 1 through 6) by using the appropriate function key. Use the scroll keys, if necessary.

Num Trap Mgrs:1

 

Next 1

2

 

F1

F2

F3

Differences Using the Async Terminal: To set the number of trap managers, select Trap Options from the main/configuration/edit/snmp menu. Figure 3-23 shows an example of the screen that appears.

3-32

December 1996

3160-A2-GB22-10