Figure 3-22. Communication Port

ACCULINK 316x DSU/CSU

9.Use the Selecting the Link Layer Protocol and Manual background keys to position the cursor under the digit you want to change. Press F1 (Up) to increment the digit or F2 (Down) to decrement the digit. In this example, you would press Manual background once to place the cursor under the middle digit in the first digit field, then press F1 (Up) once to change the 0 to a 1. Continue in this manner to change the other digits.

000.000.000.000

Up Down Save

F1 F2 F3

10.When you are through changing the IP address, you must press F3 (Save) to save the value. Otherwise, the original value will be retained.

010.155.111.222

Up Down Save

F1 F2 F3

Differences Using the Async Terminal: To set the IP address, select Modem & Communication Port Options from the main/configuration/edit/snmp menu. Figure 3-22 shows an example of the screen that appears.

 

main/configuration/edit/snmp/traps

Customer ID: New Cust

Model: ACCULINK XXXX

 

Modem & Communication Port Options

 

Communication Port IP Address: 000. 000 .000 .000

Clear

 

 

 

 

 

 

 

Communication Port Link Protocol: PPP

 

Modem Port IP Address: 000 .000 .000 . 000

Clear

 

 

 

 

 

 

 

Alternate Modem Port IP Address:

000 000 .000 . 000

Clear

Modem Port Link Protocol: PPP

 

 

Save Edit

Main

Previous Cntrl±x to Disconnect

Figure 3-22. Communication Port

Options Screen

Selecting the Link Layer Protocol

You have the option of selecting either PPP or SLIP as the link layer protocol. PPP can be used for synchronous or asynchronous operation. SLIP can be used for asynchronous operation only.

The 3160/3164 implementation of PPP supports the following:

Full negotiation of PPP's Link Control Protocol (LCP).

Active negotiation of LCP when the connection is established.

Maximum Request Unit (MRU) sizes up to

1500 bytes, but the 3160/3164 DSU/CSU will attempt to negotiate down to 500 bytes.

The 3160/3164 DSU/CSU provides a unique LCP magic number derived from the unit serial number and the elapsed time.

Full negotiation of escape characters.

Model 3160/3164 implementation of PPP does not support Link Quality Reports (LQR), compression, encryption, Password Authentication Protocol (PAP) or Challenge Authentication Protocol (CHAP).

Model 3160/3164 implementation of SLIP supports a fixed MRU size of 1006 bytes.

Before selecting the protocol, you must first select the port to be used as the communications link. Refer to the Selecting the Port section earlier in this chapter. This example assumes that the MODEM port is being used as the communications link.

To select the link layer protocol,

1.Press F3 to select Cnfig from the top-level menu screen.

DSU ESF

Stat Test Cnfig

F1 F2 F3

3-28

December 1996

3160-A2-GB22-10

Page 70