Image 35
Establishing Access Security on a Port

ACCULINK 316x DSU/CSU

6.Enter the desired ID. Press F1 (Up) and F2 (Down) to scroll up and down through the valid characters/numbers for the customer ID. Valid characters are 0 through 9, #, -, ., /, A to Z, and blank space. Press F3 (Save) to save the ID.

CustID=xxxxxxxx

Up Down Save

F1 F2 F3

Differences Using the Async Terminal: The customer ID selection is found in the main/control/miscellaneous control options menu. Select Customer Identification Name/Number from that menu.

Establishing Access Security on a Port

Although the password feature is available, it is not required as a factory default. If used, it ensures access security before device control is passed to a PC or terminal connected to a port. The password configuration option can be individually set for the COM or MODEM port, or both if security is needed on both port types. The default is none. From the front panel, set this configuration option using the Control branch. Select cnfigedituserpassword. The password itself is set separately. Refer to the section Setting/Changing a Password.

Differences Using the Async Terminal: The password is set in the main/configuration/edit/user screen. Figure 2-11 shows an example of this screen.

Customer ID: New Cust

main/configuration/edit/user

Model: ACCULINK XXXX

 

User

Self Test: _____

Front Panel Access: _____

Front Panel Pass-Through: _____

Dial-In Access: _____

Password Mode: _____

Communications Port

Modem Port

Use: _____

Use: _____

Type: _____

Type: _____

Rate: _____

Rate: _____

Character Length: _____

Character Length: _____

Parity: _____

Parity: _____

Stop Bits: _____

Stop Bits: _____

 

Long Space Disconnect: _____

Save Edit

Main Previous Cntrl±x to Disconnect

Figure 2-11. Setting the Password Option

On this screen, set the Password Mode field as appropriate.

Setting/Changing a Password

For 3160/3164 DSU/CSUs, you have the option of setting a password for security when receiving a call or the COM port connection is established. Unless you specify otherwise, the password is null.