ACCULINK 316x DSU/CSU

 

 

 

Table 3-4

 

 

 

Data Port LEDs

 

 

 

 

Name

Color

 

Meaning

 

 

 

DTR

Green

Monitors the state of interchange circuit CD (CCITT 108/1, /2) ± DTE Ready received

 

 

from the DTE.

 

 

 

ON:

DTR is being asserted by the DTE.

 

 

OFF:

DTR is not being asserted.

 

 

 

TXD

Yellow

Monitors activity on interchange circuit BA (CCITT 103) ± Transmitted Data. This is the

 

 

data sent from the DTE to the DCE on the DSU/CSU.

 

 

ON:

Ones are being received from the DTE.

 

 

OFF:

Zeros are being received from the DTE.

 

 

CYCLING: Both ones and zeros are being received from the DTE.

 

 

 

RXD

Yellow

Monitors activity on interchange circuit BB (CCITT 104) ± Received Data. This is data

 

 

sent to the DTE from the DCE on the DSU/CSU.

 

 

ON:

Ones are being sent to the DTE.

 

 

OFF:

Zeros are being sent to the DTE.

 

 

CYCLING: Both ones and zeros are being received from the DTE.

 

 

 

CTS

Yellow

Monitors the state of interchange circuit CB (CCITT 106) ± Clear to Send sent to the

 

 

DTE.

 

 

 

ON:

CTS is being asserted by the DSU/CSU.

 

 

OFF:

CTS is not being asserted.

 

 

 

RTS

Yellow

Monitors the state of interchange circuit CA (CCITT 105) ± Request to Send received

 

 

from the DTE.

 

 

 

ON:

RTS is being asserted by the DTE.

 

 

OFF:

RTS is not being asserted.

 

 

 

 