Paradyne 316x manual Displaying Device Health and Status, Self-Test Health

Models: 316x

1 211
Download 211 pages 11.69 Kb
Page 97
Image 97
Displaying Device Health and Status

Operation

Displaying Device Health and Status

To display device health and status,

1.Press F1 to select Stat from the top-level menu screen.

DSU ESF

Stat Test Cnfig

F1 F2 F3

2. From the Status screen, press F1 to select DevHS.

Status:

 

 

DevHS STest

Perf

F1

F2

F3

Alarm/status messages appear on Line 2 of the LCD in priority order (highest to lowest).

3.Use the scroll keys, if necessary, to scroll additional device health and status messages onto the LCD.

Device H/S:

OOF at DTE

F1 F2 F3

The Auto Device Health and Status screen appears when there is no activity (no keys pressed) on the active physical interface for five minutes. Only the highest priority message appears on Line 2 of the LCD.

Auto Dev H/S

OOF at DTE

F1 F2 F3

Self-Test Health

Use the Self-Test Health command to display the

results of the power-up self-test. Possible messages are listed in Table 3-10. See Chapter 2, Installation, for the procedure for performing a power-up self-test.

Differences Using the Async Terminal: To display device health and status, select Health, Test Status, and Self Test Results from the main/status menu. This screen (Figure 2-10 in Chapter 2) displays all the test results on a device. Note that Auto Device Health and Status is not supported on the async terminal.