OPERATORS GUIDE
Document No. 3160-A2-GB22-10
ACCULINK 316x DATA SERVICE UNIT
CHANNEL SERVICE UNIT INCLUDES TERMINAL USER INTERFACE
Warranty, Sales, and Service Information
316x Data Service Unit/Channel Service Unit
ACCULINK
Trademarks
Important Safety Instructions
Notices
ACCULINK 316x DSU/CSU
CC DGD D C G C D CC
D D
Government Requirements and Equipment Return
United States
NOTICE TO USERS OF THE UNITED STATES TELEPHONE NETWORK
316x DSU/CSU Facility Interface Codes
Canada
NOTICE TO USERS OF THE CANADIAN TELEPHONE NETWORK
Page
Table of Contents
2. Installation
Preface
1. Introduction
4. Maintenance
3. Operation
Glossary Index
Appendices
Example Shared Access to Network-Based Services Configuration
Multiport T1 DSU/CSU in a Fractional T1 Network Configuration
List of Figures
Front Panel Emulation Screen Models 3160/3164 DSU/CSUs
Example Port Channel Configuration Tables Ports 1 and 2 Worksheet
Example Port Channel Configuration Tables Ports 3 and 4 Worksheet
Integral Modem Cable Feature Number 3150-A1-210
COM Port-to-PC Cable Feature Number 3100-F1-550
Models 3160/3614 DSU/CSUs Rear Panel Connectors
ACCULINK Models 3160/3164 DSU/CSUs Technical Specifications
ACCULINK Model 3161 DSU/CSU Technical Specifications
List of Tables
D-1 T1 Network Interface Connector J4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-2 D-2 T1 Network Interface Connector DA15P . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-3 D-3 DSX-1 DTE Interface Connector J3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-4 D-4 Integral Modem Service Port Connector J5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-5 D-5 Extended Management Port Connector J7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-6 D-6 COM Port Connector J6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-8 D-7 EIA-530A Port Interface Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-9 D-8 RS449 Port Interface Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-10 D-9 V.35 Port Interface Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-12 D-10 DC Power Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-14 D-11 External Clock Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-15 D-12 Slide Latch Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D-16
Carrier Installation Manual
Central Office Power Unit
Installation Guide
Preface
Introduction
Overview
Features
Alarm Interface
Integral Modem
User Interface
Front Panel Access Control Feature
Front Panel Emulation
Front Panel Pass-Through
Async Terminal Interface Support
ACCULINK 316x DSU/CSU Physical Description
Standalone Model 3160/3164 DSU/CSUs
3160/3164 DSU/CSU Front Panel
3160/3164 DSU/CSU Rear Panel
Figure 1-1. 3160 DSU/CSU Front Panel
ACCULINK
Figure 1-2. 3164 DSU/CSU Front Panel
ACCULINK
Figure 1-3. 3160 DSU/CSU Rear Panel
Figure 1-4. 3164 DSU/CSU Rear Panel
ACCULINK 316x DSU/CSU
December
Function
Models 3160/3164 DSU/CSUs Rear Panel Connectors
Connector Name
Auxiliary Backplane Connectors
Carrier-Mounted Model 3161 DSU/CSU
Model 3161 Front Panel Functions
Model 3161 DSU/CSU Rear Panel
Figure 1-6. Auxiliary Backplane
Introduction
3160-A2-GB22-10
December
Overview
Installation
Planning
Figure 2-1. Example Point-to-Point Configuration
SERVICES
NETWORK
In addition, a 3160 DSU/CSU, acting as an SNMP agent, can be connected to and managed from an SNMP management system in one of two ways
Figure 2-4. Central-Site T1 Termination Configuration
FRACTIONAL T1
Installation
NETWORK
Figure 2-5. Serial Connection to SNMP
Figure 2-6. Serial Connection through a Router to SNMP
ACCULINK 316x DSU/CSU
December
Box Contents
Quick Start Procedure
HANDLING PRECAUTIONS FOR STATIC-SENSITIVE DEVICES
One ACCULINK 3160/3164 DSU/CSU Reference Card
Figure 2-7. +24 Vdc Power Supply Pinouts
Optional Power Selection
Installing the +24 Vdc Power Supply
Installing the Single ±48 Vdc Power Supply
Figure 2-8. ±48 Vdc Single Source Power Supply Pinouts
Installing the Redundant ±48 Vdc Power Supply
Figure 2-9. ±48 Vdc Redundant Source Power Supply Pinouts
Power-Up Self-Test
Self-Test In Progress
Self-Test Passed
Self-Test Failed nnnnnnnn
Figure 2-10. Health and Status Results Screen
Selecting a Model DSU/CSU
DSU/CSU Identity
4. The following screens appear in the order listed
Figure 2-11. Setting the Password Option
Establishing Access Security on a Port
Setting/Changing a Password
Figure 2-12. Password Configuration Screen
main/control/miscellaneous
3160/3164 DSU/CSU Cabling
Figure 2-13. 3160/3164 DSU/CSU Cabling Configurations
Installation
3160-A2-GB22-10
December
Factory Default Configuration Options
Installing Front Panel Emulation Software
Do you want to overwrite the directory? appears
6. PRESS ENTER
Enabling/Disabling the Front Panel
3160/3164 DSU/CSU User Interface Access Security
Changing User Interface Access Security
Operation
Controlling the DSU/CSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-61 Acquiring/Releasing the User Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-62 Acquiring the Active Physical Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-62 Releasing the Active Physical Interface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-62 Using the Integral Modem . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-63 Initiating a Call for Front Panel Pass-Through Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-63 Initiating a Call for PC, ASCII Terminal/Printer, Async Terminal, or SNMP Operation . . . . . . . 3-64 Entering a Password to Gain Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-65 Disconnecting the Modem Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-66 Disconnecting Using the Disconnect Command . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-66 Disconnecting Using Front Panel Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-66 Entering Numbers in the Phone Directories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-67 Deactivating the Alarm Relay
Operating the Front Panel
Figure 3-1. 3160 DSU/CSU Front Panel
Figure 3-3. Shared Diagnostic Control Panel SDCP
Figure 3-2. Model 3161 DSU/CSU Faceplate
INDICATORS
OK Alarm BckUp Test
Device Health and Status Messages
Other Displays
Context-Sensitive Menu
Keypad
LEDs
Figure 3-6. LEDs
System LEDs
Name
Color
Meaning
NETWORK Interface LEDs
Name
Color
Meaning
DSX-1 Drop/Insert Port LEDs
Name
Color
Meaning
Data Port LEDs
Name
Color
Meaning
Displaying LED Conditions on the Front Panel
Selecting the DSX-1 or a Port for LED Display
Figure 3-7. LED Status Screen
Front Panel Emulation on a PC
Figure 3-8. LED Display Selection Screen
Figure 3-9. Front Panel Emulation Screen Models 3160/3164 DSU/CSUs
Figure 3-10. Front Panel Emulation Screen Model 3161 DSU/CSU
Test Jacks
Front Panel Emulation Screen Icons
Icon
Figure 3-11. 3160/3164 DSU/CSU Test Jacks
Figure 3-13. Test Jack Block Diagram
Figure 3-12. 3161 DSU/CSU Test Jacks
Operation
3160-A2-GB22-10
Configuring the DSU/CSU
Configuration Option Areas
Configuration Options
Test Jack Functions
Configuration Procedures
Figure 3-14. Configuration Branch for the Front Panel
Operation
3160-A2-GB22-10
Displaying/Editing Configuration Options
Figure 3-15. Configuration Branch for the Async Terminal
Figure 3-16. Load From Screen
Figure 3-17. Save To Screen
main/configuration
main/configuration/load
Saving Edit Changes
Figure 3-18. Save Edit screen
Selecting/Copying to a Specific Port
Selecting a Specific Port
Figure 3-19. Port Options Configuration Worksheets
Prt1
Value
Options
To Copy to One or All Ports
Figure 3-20. SNMP System Options Screen
Configuring the 3160/3164 DSU/CSU for SNMP Management
Selecting the Port
DSU ESF Stat Test Cnfig
Setting the IP Address
Figure 3-21. Edit User Screen
DSU ESF Stat Test Cnfig
Selecting the Link Layer Protocol
Figure 3-22. Communication Port Options Screen
Specifying the Community Names and Access Types
Load from
SNMP Traps
Enterprise-Specific Trap Definitions
Trap Value
Event
Selecting the Number of Trap Managers
Configuring an IP Address for SNMP Trap Manager
Figure 3-23. Trap Options Screen
Configuring DS0 Channels
Trap n IP Adr Next Edit Clear
Figure 3-24. Example Channel Allocation
Operation
3160-A2-GB22-10
December
Network T1 Interface
Network Channel
Allocation
DSX-1 DTE Drop/Insert T1 Interface
Config
DTE Chan
Assign
Voice
Port Chan
Conf
Options
Value
Port Chan
Options
Value
Conf
Display Channel Symbols
Symbol
Displaying DS0 Channel Assignments
Meaning
Customer ID New Cust
Figure 3-29. Display Channels Screen
main/configuration/edit/channel/display
Allocating Data Ports
DSU ESF Stat Test Cnfig
Load from
Activ
Block Channel Assignment Method Example
ACAMI Channel Assignment Method Example
Port Rate384 Next 64
Start AtClear Next Clear N1
Assign ByBlock Next Block ACAMI
Individual Channel Assignment Method Example
Load from
Figure 3-30. DTE Assignment Screen
Figure 3-31. DTE Voice Assignment Screen
Differences Using the Async Terminal To clear DS0
Clearing DS0 Channel Allocation
Figure 3-32. Common Clocking Configurations
Timing
Configuring for Network Timing Example
Configuring for External Timing Example
Selecting the Shared Communication Port
Checking the Status of the DSU/CSU
Device Health and Status
Figure 3-33. Status Branch
Figure 3-34. Async Terminal Status Branch
Description
Health and Status Messages
Message
Displaying Device Health and Status
Self-Test Health
Displaying Self-Test Results
Self-Test Health Messages
Message
Description
Performance Report
1 of Performance Registers
Register
Interval Description
2 of Performance Registers
Figure 3-35. Carrier Telco and User Register Organization
Register
Interval Description
Displaying User Performance Registers
Clearing User Performance Registers
Figure 3-36. Telco Performance Report Screen
Figure 3-37. User Performance Report Screen
ACCULINK 316x DSU/CSU
Figure 3-39. Control Branch for the Async Terminal
Controlling the DSU/CSU
Figure 3-38. Control Branch
Acquiring/Releasing the Active Physical Interface
Acquiring the Active Physical Interface
Releasing the Active Physical Interface
User I/F active
Using the Integral Modem
Initiating a Call for Front Panel Pass-Through Operation
Page
Entering a Password to Gain Access
Figure 3-40. Call Setup Screen
Disconnecting Using Front Panel Keys
Disconnecting the Modem Connection
Disconnecting Using the Disconnect Command
Entering Numbers in the Phone Directories
Figure 3-41. Disconnect Screen
Valid Phone Number Characters
Valid Characters
Restrictions
to a lower digit. The key inserts blanks
Deactivating the Alarm Relay
Starting Front Panel Emulation
Using the Async Terminal Feature
Setting Interface Options
Async Terminal Interface Configuration Options
COM Port Connection
Entering a Password
Figure 3-42. Password Access Screen
Activating Interface Option Changes
Initiating an Async Terminal Session
Menu Selection Screens
Edit and Display Screens
To return to the top-level menu from any screen
To terminate a session from any screen, enter Ctrl-x
Hard-Key Representations for Edit Screens
Usage
Function Representations for Edit Screens
Function Key
Terminating a Session
Function Representations for Display Screens
Function Key
Usage
Overview
Maintenance
Troubleshooting
Alarms
Continuous Loss Of Signal at the x Interface
Alarm Cleared. Loss of Signal condition at the x Interface
Alarm Clear. Out of Frame condition at the x Interface
Figure 4-2. Test Branch for Async Terminal
Test Commands
Figure 4-1. Test Branch
Remote Loopback Tests
Sending a Line Loopback Up or Down
For Networks
For Channels
Sending a V.54/ANSI FT1 Activation/Deactivation
Local Loopback Tests
Starting a Line Loopback
Valid Loopback Combinations
DCLB
DTLB
Starting a Payload Loopback
Starting a DTE Loopback
DSU ESF Stat Test Cnfig
Test Rlpbk Lpbk Ptrns
Starting a Repeater Loopback
Starting a Data Channel Loopback
Starting a Data Terminal Loopback
HANDLING PRECAUTIONS FOR STATIC-SENSITIVE DEVICES
Abort Test Name
DTE-initiated Loopbacks
Aborting Loopbacks
Send Name and Dest
Test Patterns
Sending Test Patterns
Monitoring Test Patterns
Valid Send Test Pattern Combinations
QRSS Network
QRSS Port
Aborting Test Patterns
Lamp Test
Starting a Lamp Test
Abort Send or Mon
Aborting a Lamp Test
Displaying DSU/CSU Test Status
Test Status Messages
Message
Description
Resetting the DSU/CSU
Downloading Software
4. Press F2 to select Reset
December
Front Panel Menu A
3160-A2-GB22-10
3160-A2-GB22-10
ACCULINK 316x DSU/CSU
December
December
Front Panel Menu
3160-A2-GB22-10
Technical Specifications B
ACCULINK Models 3160/3164 DSU/CSUs Technical Specifications
Specifications
Table B-1 1 of
Table B-1 2 of
ACCULINK Models 3160/3164 DSU/CSUs Technical Specifications
Specifications
PHYSICAL DIMENSIONS
Table B-2 1 of ACCULINK Model 3161 DSU/CSU Technical Specifications
Specifications
POWER REQUIREMENTS
POWER CONSUMPTION AND
Table B-2 2 of ACCULINK Model 3161 DSU/CSU Technical Specifications
Specifications
WEIGHT
Criteria
Configuration Options C
DTE Interface Configuration Options
Port Configuration Options
Network Interface Configuration Options
DTE Interface Configuration Options
Table C-1 1 of DTE Interface Configuration Options
Context-Sensitive Menu
DTE Port Enab Next Enab Disab Prev
Send Ones Enab Next Enab Disab Prev
Table C-1 2 of DTE Interface Configuration Options
Extrn DLB Disab Next Enab Disab Prev
Port Configuration Options
Port Configuration Options
1 of
Table C-2
Table C-2 2 of Port Configuration Options
Port LB Disab Factory 1 Both Factory Next Disab DTLB DCLB Both Prev
All Ones Both Next Disab DTR RTS Both Prev
Rcv Yellow Halt Next None Halt Prev
Table C-2 3 of Port Configuration Options
Tx Clock Int Next Int Ext Prev
Invert TxC Disab Next Enab Disab Prev
Invert Data Disab Next Enab Disab Prev
Network Interface Configuration Options
Table C-3 1 of Network Interface Configuration Options
NET Framing ESF Factory 1 D4 Factory Next D4 ESF Prev
NET Coding B8ZS Factory 1 AMI Factory Next AMI B8ZS Prev
Bit Stuff Next 62411 Part68 Disab Prev
Table C-3 2 of Network Interface Configuration Options
NET PLB Enab Next Enab Disab Prev
Channel Configuration Options
Table C-4 DTE Channel Configuration Options
DTE Channels Assign Voice
Value Meaning
Table C-5 1 of Data Port Channel Configuration Options
Prt1, 2, 3, or
Assign To NET Next NET DTE Prev
Assign By Block Next Block ACAMI Chan Prev
Table C-5 2 of Data Port Channel Configuration Options
Start At Clear
Next
Clear
General Configuration Options
Table C-6 General Configuration Options
Gen Yellow Enab Next Enab Disab Prev
Clock Src NET Next NET DTE Prt1 Int Ext Prev
User Interface Configuration Options
Table C-7 1 of User Interface Configuration Options
FP Access Enab Next Enab Disab Prev
Password None Next None Modem Com Both Prev
Table C-7 2 of User Interface Configuration Options
MasterComDisab Next Enab Disab Prev
Com Use ASCII Next SNMP ASCII Term Prev
Com Type Async Next Async Sync Prev
Table C-7 3 of User Interface Configuration Options
Com Rate Next 1.2 2.4 4.8 9.6 14.4 19.2 Prev
Char Length Next 7 8 Prev
CParity None Next None Even Odd Prev
Table C-7 4 of User Interface Configuration Options
Modem Type Async Next Async Sync Prev
Modem Rate Next 1.2 2.4 Prev
MChar Len Next 7 8 Prev
Alarm Configuration Options
Table C-8 1 of Alarm Configuration Options
Alrm Msg Disab Next Disab Modem Com Both Prev
SNMP Trap Disab Next Enab Disab Prev
Table C-8 2 of Alarm Configuration Options
Dial Delay Next 1 2 3 4 5 6 7 8 9 10 Prev
DialOut Disab Next Enab Disab Prev
Call Retry Disab Next Enab Disab Prev
AlrmRelay Disab Next Enab Disab Prev
Table C-8 3 of Alarm Configuration Options
Err Rate 10E-4 Next 10E-4 10E-5 10E-6 10E-7 10E-8 10E-9 Prev
SNMP Configuration Options
Table C-9 1 of General SNMP Configuration Options
Access 1 Read Next Read R/W Prev
System Name Clear Next Edit Clear Prev
Table C-9 2 of General SNMP Configuration Options
Access 2 Read Next Read R/W Prev
Com IP Adr Clear Next Edit Clear Prev
Com Link PPP Next PPP SLIP Prev
Table C-10 1 of SNMP Trap Configuration Options
Num Trap Mgrs Next 1 2 3 4 5 6 Prev
Trap n IP Adr Clear Next Edit Clear Prev
Gen Trap Both Next Disab Warm Auth Both Prev
Trap I/F All Next NET DTE T1s Ports All Prev
Table C-10 2 of SNMP Trap Configuration Options
Link Trap Both Next Disab Up Down Both Prev
Cables
T1 Network Connector Interface
Pin Assignments D
Table D-1 T1 Network Interface Connector J4
Signal
Pin Number
ACCULINK 316x DSU/CSU
Table D-2 T1 Network Interface Connector DA15P
RJ48C
DA15P
Signal
Figure D-3. DSX-1 Cable Table D-3 DSX-1 DTE Interface Connector J3
DSX-1 Port DTE Interface
Signal
Pin Number
Integral Modem Service Port Interface
Figure D-4. Integral Modem Cable Feature Number 3150-A1-210 Table D-4
Integral Modem Service Port Connector J5
Signal
Table D-5 Extended Management Port Connector J7
AUX Port Interface
Direction
Signal
Figure D-5. COM Port-to-PC Cable Feature Number 3100-F1-550
COM Port Interface
Table D-6 COM Port Connector J6
Signal
Direction
Pin Number
EIA-530A DB25 Port Interface Connector
Table D-7 EIA-530A Port Interface Connector
Circuit
CCITT
RS449 Port Interface Connector
Table D-8 RS449 Port Interface Connector
Signal
Circuit
Pin Assignments
3160-A2-GB22-10
December
D-11
V.35 Port Interface Connector
Table D-9 V.35 Port Interface Connectors
Signal
CCITT
Figure D-8. EIA-530A to V.35 Adapter Cable Feature Number 3100-F1-570
Pin Assignments
3160-A2-GB22-10
December
Power Cable
Power Input Connector
Figure D-9. DC Power Cable Feature Number 3100-F1-520
Table D-10 DC Power Connector
External Clock Connector
Figure D-10. External Clock Connector Table D-11
External Clock Connector
Signal
Figure D-11. Slide Latch Adapter Cable Feature Number 3100-F1-560
Table D-12 Slide Latch Connector
Slide Latch Adapter
DA15S
SNMP MIB Objects E
Management Information Base MIB II RFC
RS- 232-like MIB RFC
Number of Ports ± ªrs2 32Numberº Object rs232
System Group Supported
System Group ± ªsysServicesº Object system
System Group, MIB
System Group ± ªsysDescrº Object system
System Group ± ªsysObjectIDº Object system
Interface Group, MIB
Interface Group ± ªifDescrº Object ifEntry
Interface Group ± ªifTypeº Object ifEntry
Interface Group ± ªifMtuº Object ifEntry
Interface Group ± ªifAdminStatusº Object ifEntry
Interface Group ± Input Counters objects ifEntry 10 to ifEntry
Interface Group ± Output Counters objects ifEntry 16 to ifEntry
IP Group ± ªipNetToMediaTableº Object ip
ICMP Group, MIB
UDP Group, MIB
Near End Group ± ªdsx1TimeElapsedº Object dsx1ConfigEntry
Near End Group ± ªdsx1ValidIntervalsº Object dsx1ConfigEntry
Near End Group ± ªdsx1LineTypeº Object dsx1ConfigEntry
Near End Group ± ªdsx1LineCodingº Object dsx1ConfigEntry
Near End Group ± ªdsx1SendCodeº Object dsx1ConfigEntry
Near End Group ± ªdsx1CircuitIdentifierº Object dsx1ConfigEntry
Near End Group ± ªdsx1LoopbackConfigº Object dsx1ConfigEntry
Near End Group ± ªdsx1LineStatusº Object dsx1ConfigEntry
Near End Group ± ªdsx1TransmitClockSourceº Object dsx1ConfigEntry
Near End Group ± ªdsx1Fdlº Object dsx1ConfigEntry
Near End Group ± The DS1 Current Table Objects dsx1CurrentEntry
Near End Group ± The DS1 Interval Table Objects dsx1IntervalEntry
RS-232-like MIB RFC
Near End Group ± The DS1 Total Table Objects dsx1TotalEntry
Far End Group, DS1/E1 MIB
The DS1 Fractional Group, DS1/E1 MIB
Number of Ports ± ªrs232Numberº Object rs232
General Port Table, RS-232-like MIB
General Port Table ± ªrs232PortIndexº Object rs232PortEntry
General Port Table ± ªrs232PortOutSigNumberº Object rs232PortEntry
Input Signal Table, RS-232-like MIB
Input Signal Table ± ªrs232InSigNameº rs232InSigEntry
Input Signal Table ± ªrs232InSigStateº rs232InSigEntry
Input Signal Table ± ªrs232InSigChangesº rs232InSigEntry
Output Signal Table ± ªrs232OutSigNameº rs232OutSigEntry
Output Signal Table ± ªrs232OutSigStateº rs232OutSigEntry
Output Signal Table ± ªrs232OutSigChangesº rs232OutSigEntry
Generic-Interface MIB Extensions RFC
Generic Interface Test Table ± ªifExtnsTestResultº Object ifExtnsTestEntry
Troubleshooting Table F
Table F-1 1 of Troubleshooting
Symptom
Solutions
Table F-1 2 of Troubleshooting
Symptom
Solutions
Possible Cause
December
Configuration Worksheets G
3160-A2-GB22-10
Value
Options
Value
Options
Prt1
Value
Options
Prt2
Network T1 Interface
Network Channel
Allocation
DSX-1 DTE Drop/Insert T1 Interface
Config
DTE Chan
Assign
Voice
Port Chan
Options
Value
Conf
Port Chan
Options
Value
Conf
Alarm
General Options
User Options
SNMP Gen
Feature Number
3000 Series Carrier Installation
Equipment List H
Equipment
Glossary
Async Terminal
Auxiliary Backplane
B8ZS
Yellow Alarm
LOFC
PSTN
QRSS
Index
Page