Log > Automation
Syslog Event Redundancy Filter (seconds) - The Syslog Event Redundancy Filter setting prevents repetitive messages from being written to Syslog. If duplicate events occur during the period specified in the Syslog Event Redundancy Rate field, they are not written to Syslog as unique events. Instead, the additional events are counted, and then at the end of the period, a message is written to the Syslog that includes the number of times the event occurred.
The Syslog Event Redundancy Rate default value is 60 seconds and the maximum value is 86,400 seconds (24 hours). Setting this value to 0 seconds sends all Syslog messages without filtering.
Syslog Format - You can choose the format of the Syslog to be Default or WebTrends. If you select WebTrends, however, you must have WebTrends software installed on your system.
Enable ViewPoint Settings - Check this box to override Syslog settings, if you’re using SonicWALL ViewPoint for your reporting solution.
SONICWALL SONICOS STANDARD 3.0 ADMINISTRATOR’S GUIDE | 305 |