Configuring the Modem Interface (TZ 170 SP)

Failover

The Failover page in the Modem Setting window includes the same settings on the Modem > Failover page. If you configured the failover settings on the Modem > Failover page, they are displayed in the Failover page. If you have not configured Failover settings, use the following instructions to configure the Failover Settings:

1Select Enable WAN Failover.

2Select Enable Preempt Mode if you want the primary WAN Ethernet interface to take over from the secondary modem WAN interface when it becomes active after a failure. If you do not enable Pre-empt Mode, the secondary WAN modem interface remains active as the WAN interface until you click Disconnect.

3Select Enable Probing. Probing for WAN connectivity occurs over the Ethernet connection, the dial-up connection, or both. When probing is disabled on the Ethernet link, the SonicWALL security appliance only performs link detection. If the Ethernet connection is lost for a duration of 5-9 seconds, the SonicWALL security appliance considers the Ethernet connection to be unavailable. If the Ethernet link is lost for 0-4 seconds, the SonicWALL security appliance does not consider the connection to be lost. If you are swapping cables quickly, unnecessary WAN failover does not occur on the SonicWALL security appliance. If probing is enabled and the cable is unplugged, the 5-9 seconds link detection does not occur. Instead, the probing rules apply to the connection using the parameters configured for Probe Interval (seconds) and Failover Trigger Level (missed probes) settings. If probing is enabled on dialup, the dialup connection is terminated and re-established when probing fails over the modem.

4Select an option from the Probe through menu. Select Ethernet Only to probe the Ethernet WAN connection and failover to the modem when the connection is lost. Select Modem Only to probe a dial-up connection and have the modem redial when the dial-up connection is lost. Select Modem and Ethernet to enable both types of probing on the SP.

5Enter the IP address for the probe target in the Probe Target (IP Address) field. The Probe IP address is a static IP address on the WAN. If this field is left blank, or 0.0.0.0 is entered as the address, the Probe Target is the WAN Gateway IP address.

Note: The probe is a ping sent to the specified IP address to determine Internet connectivity.

6Select ICMP Probing or TCP Probing from the Probe Type options. If you select TCP Probing, enter the TCP port number in the TCP port field.

7In the Probe Interval (seconds) field, enter the amount of time between probes to the Probe Target. The default value is 5 seconds. To deactivate the Probe Detection feature, enter 0 as the