Tektronix 071-0855-05 user manual SENSeANALysisG826AMSFARALL

Models: 071-0855-05

1 253
Download 253 pages 20.53 Kb
Page 147
Image 147

Reference: Remote Commands ~ Command Description

:SENSe:ANALysis:G826A:MS:FAR

This query returns the value of the specified Far-End Multiplexor Section parameter from G.826 analysis of received data.

Syntax :SENSe<slot>:ANALysis:G826A:MS:FAR? <Enum>

Parameter

Description

ETIME

Elapsed time

EB_C

Errored blocks

EB_R

Errored block ratio

BBE_C

Background block errors

BBE_R

Background block error ratio

EFS_C

Error-free seconds

EFS_R

Error-free seconds ratio

ES_C

Errored seconds

ES_R

Errored second ratio

SES_C

Severely errored seconds

SES_R

Severely errored second ratio

CSES_C

Consecutive SES periods

UAS_C

Unavailable seconds

UAS_R

Unavailable seconds error ratio

:SENSe:ANALysis:G826A:MS:FAR:ALL

This query returns the values of all of the Far-End Multiplexor Section parameters from G.826 analysis of received data. The parameters are returned in the order in which they are listed under :SENSe:ANALysis:G826A:MS:FAR.

Syntax :SENSe<slot>:ANALysis:G826A:MS:FAR:ALL?

3-16

OTS9100 User Manual

Page 147
Image 147
Tektronix 071-0855-05 user manual SENSeANALysisG826AMSFARALL