Reference: Remote Commands ~ Command Description

:SENSe:OPTical:THReshold:AUTO

This command sets the auto-correct option for the receiver set point control to either on (1) or off (0). When set with to the on (1) value, the system sets the receiver point with its default value, and disallows any further manual setting. When set to the off (0) value, the user can manually adjust the receiver set point. The query version of this action returns the current setting for the auto-correct value.

Syntax :SENSe<slot>:OPTical:THReshold:AUTO? :SENSe<slot>:OPTical:THReshold:AUTO <Boolean>

:SENSe:OVERhead:MONItor:CHANnel

This command selects the particular channel of the received signal from which overhead data is monitored. The query form returns the current setting.

Syntax :SENSe<slot>:OVERhead:MONItor:CHANnel? :SENSe<slot>:OVERhead:MONItor:CHANnel <NR1>

:SENSe:SIGNal:STANdard

This command sets individual OTS9100 modules to the SONET or SDH signal mode. The query form returns the current setting.

Syntax :SENSe <Slot>:SIGNal:STANdard?

:SENSe <Slot>:SIGNal:STANdard SONET  SDH

Parameters

Description

SONET

Set module to SONET signal mode

SDH

Set module to SDH signal mode