Operating Basics: User Interface

LED Window

Activating the LED Status window provides the user with a virtual LED status panel for the OTS9100 receiver(s), as shown in Figure 2-7. The virtual indicators found on this window provide error conditions, both current and historical, for

all traditional receiver error LEDs. The LED Status window may be activated through the View menu or from the toggle key on the toolbar.

Each condition has two separate indicators, the one on the right is the Current condition and the indicator on the left is the History. The Current indicators will turn red and the History indicators will turn yellow if an error condition currently exists. Once the condition has been removed, the red Current indicator will turn off. The yellow History indicator will remain on until a new test has been started or until the Clear History button is clicked.

See Table 2-1 for a description of each indicator.

Note: Extended Panel information can be viewed with scrolling LED bars, this feature is only enabled when a panel is extended beyond the framework.

Three LED panel views can be enabled from within the OTS9000 application, the Module Summary Panel, the Slot Signal Panel and the User Customizable Signal Panel.

Note: The LED panels display Receiver information only. When only one receiver has been selected from the navigation bar no user selectable signals will be available.

Click on the drop down menu for the LED panel to access the possible choices for the LED panel. Each selection provides specific controls for the active LED. The choices are Module Signal, Slot Signal and User Selected Signal. Each state is described below.

AGGREGATE

SIGNAL

S

E

C

T

I

O

N

L

I

N

E

P

A

T

H

2-18

OTS9100 User Manual

Page 47
Image 47
Tektronix 071-0855-05 user manual LED Window