Tektronix 071-0855-05 user manual SENSeDATASPESTUFfing, SENSeDATASTRUcture, SENSeDATATOHSTM1AALL

Models: 071-0855-05

1 253
Download 253 pages 20.53 Kb
Page 163
Image 163

Reference: Remote Commands ~ Command Description

:SENSe:DATA:SPE:STUFfing

This command controls the receiver’s treatment of columns 30 and 59, which can be used for SPE fixed byte stuffing. When enabled, these columns are treated as stuffing columns and are not considered part of the payload. When disabled, columns 30 and 59 are treated as part of the payload. This command is applicable only to STS-1 structure. The query form returns the current setting.

Syntax: :SENSe<slot>:DATA:SPE:STUFfing? :SENSe<slot>:DATA:SPE:STUFfing? <Boolean>

:SENSe:DATA:STRUcture

This command sets the receiver structure. The query form returns the current setting.

Syntax: :SENSe<slot>:DATA:STRUcture? :SENSe<slot>:DATA:STRUcture <Enum>

Parameters

Description

G10C

Bulk data at 10 Gb/s

G2P5C

Bulk data at 2.5 Gb/s

M622C

Bulk data at 622 Mb/s

M155C

Bulk data at 155 Mb/s

M51A

Bulk data at 51 Mb/s (SONET only)

:SENSe:DATA:TOH:STM1A:ALL

This query returns a block of data representing the Transport Overhead data from an STM-1 in the received signal.

There are 81 bytes - three groups of 27 - in the block returned, representing the STS-1 overhead data for each STS-1 in the STM-1.

Syntax :SENSe<slot>:DATA:TOH:STM1A:ALL?

:SENSe:DATA:TOH:STS1A:ALL

This query returns a block of data representing the Transport Overhead data from an STS-1 in the received signal.

There are 27 bytes in the block returned. These correspond to the overhead bytes A1, A2, J0, B1, E1, F1, D1..D3, H1..H3, B2, K1, K2, D4..D12, S1, Z2, E2.

Syntax :SENSe<slot>:DATA:TOH:STS1A:ALL? [<NR1>]

3-32