Reference: Remote Commands ~ Command Description

:SENSe:ANALysis:G826A:PATH:FAR:ALL

This query returns the values of all of the Far-End Path parameters from G.826 analysis of received data. The parameters are returned in the order in which they are listed under the heading :SENSe:ANALysis:G826A:PATH:FAR. Ratios are returned as NR3 values, other parameters as NR1 values.

Syntax: :SENSe<slot>:ANALysis:G826A:PATH:FAR:ALL?

:SENSe:ANALysis:G826A:PATH:NEAR

This query returns the value of the specified Near-End Path parameter from G.826 analysis of received data. Ratios are returned as NR3 values, other parameters as NR1 values.

Syntax: :SENSe<slot>:ANALysis:G826A:PATH:NEAR? <Enum>

Parameters

Description

ETIME

Elapsed time

EB_C

Errored blocks

EB_R

Errored block ratio

BBE_C

Background block errors

BBE_R

Background block error ratio

EFS_C

Error-free seconds

EFS_R

Error-free seconds ratio

ES_C

Errored seconds

ES_R

Errored second ratio

SES_C

Severely errored seconds

SES_R

Severely errored second ratio

CSES_C

Consecutive SES periods

UAS_C

Unavailable seconds

UAS_R

Unavailable seconds error ratio

:SENSe:ANALysis:G826A:PATH:NEAR:ALL

This query returns the values of all of the Near-End Path parameters from G.826 analysis of received data. The parameters are returned in the order in which they are listed under the heading :SENSe:ANALysis:G826A:PATH:NEAR. Ratios are returned as NR3 values, other parameters as NR1 values.

Syntax: :SENSe<slot>:ANALysis:G826A:PATH:NEAR:ALL?