Reference: Remote Commands ~ Command Description

:SENSe:DATA:CHANnel

This command selects the active channel for the received signal. The query form returns the current setting.

Syntax: :SENSe<slot>:DATA:CHANnel? :SENSe<slot>:DATA:CHANnel <NR1>

:SENSe:DATA:IP:PAYLoad:PATTern

This command selects the test pattern inserted as IP payload into the received signal. The query form returns the current setting.

Syntax :SENSe<slot>:DATA:IP:PAYLoad:PATTern? :SENSe<slot>:DATA:IP:PAYLoad:PATTern <Parameter>

Parameters

Description

PRBS31A

ITU standard PRBS 2^31-1 pattern

PRBS31I

Inverted PRBS 2^31-1 pattern

USER

Constant 16-bit user-specified data

:SENSe:DATA:IP:PAYLoad:PATTern:UDATA

This command specifies the data value inserted into the received signal when constant data is selected for the IP test pattern. The query form returns the current setting.

Syntax :SENSe<slot>:DATA:IP:PAYLoad:PATTern:UDATA? :SENSe<slot>:DATA:IP:PAYLoad:PATTern:UDATA <NR1>

:SENSe:DATA:IP:STReam:INDEX

This query form returns the current setting.

Syntax :SENSe<slot>:DATA:IP:STReam:INDEX?

:SENSe:DATA:PATH:TRACe

This query returns the most recently received J1 path trace type (length) and data. See the command :SOURce:DATA:PATH:TRACe for the formats of the enum and block values returned. The data bytes are returned in standard IEEE-488 block data format.

Syntax: :SENSe<slot>:DATA:PATH:TRACe?