Reference: Remote Commands ~ Command Description
3-76 OTS9100 User Manual
:SYSTem:CONFig:MODule:TYPE
This query accepts a module slot number, between 1 and 16, and returns a str ing identifying the
Tektronix module in the specified slot. If the slot specified does not c ontain an OTS system, this query
returns the string 'Non-Tek device or empty slot'.
Syntax :SYSTem:CONFig:MODule:TYPE? <NR1>
:SYSTem:CONFig:MODule:VARIANT
This query accepts a module slot number, between 1 and 16, and returns the m odule variant as a
decimal number, or 0 if there is no variant information. "Variant" is the module sub-type, for example, the
Optics card may be a Transceiver, Transmit only, or Receive onl y version
Syntax :SYSTem:CONFig:MODule:VARIANT? <NR1>
:SYSTem:CONFig:MODule:VERSion
This query accepts a module slot number, between 1 and 16, and returns the v ersion information
associated with the Tektronix module in the specified slot. The string return ed has the format
Mnn.nn,Unn.nn,Dnn.nn,Xnn.nn,Fnn.nn and contains major and minor versi on numbers for the module
itself and its utility, driver, FPGA file, and firmware. Fields that are n ot applicable to the particular module
are returned as 0. If the specified slot does not contain an OTS system, this query returns an error.
Syntax :SYSTem:CONFig:MODule:VERSion? <NR1>
:SYSTem:CONFig:SLOTs
This query returns the number of module slots in the system.
Syntax :SYSTem:CONFig:SLOTs?
:SYSTem:DESCription:SETUp
This command sets a text string that is stored with the current system s ettings and which may be used to
annotate or identify the instrument setup. The query form returns the current s etting.
Syntax :SYSTem:DESCription:SETUp?
:SYSTem:DESCription:SETUp <String>