Reference: Remote Commands ~ Command Description

:SENSe:MEASure:PATH:CUMUlative:ALL

This query returns the values of all of the parameters of the :SENSe:MEASure:PATH:CUMUlative? query. The parameters are returned in the order in which they are listed under the heading :SENSe:MEASure:PATH:CUMUlative. Ratios are returned in NR3 format; other values are returned in NR1 format

Syntax: :SENSe<slot>:MEASure:PATH:CUMUlative:ALL?

:SENSe:MEASure:PATH:WINDow

This query returns the value of the specified result parameter as measured during the most recent 'N' seconds. The duration 'N' of the measurement window is set by the :SENSe:MEASure:WINDow:SIZE command.

Syntax: :SENSe<slot>:MEASure:PATH:WINDow? <Enum>

Parameters

Description

B3_C

B3 errors

B3_ES

B3 errored seconds

B3_ER

B3 error ratio

REI_C

Path REI errors

REI_ES

Path REI errored seconds

REI_ER

Path REI error ratio

AIS_ES

Path AIS errored seconds

RDI_ES

Path RDI errored seconds

PLM_ES

Path Label Mismatch errored seconds

UNEQ_ES

Path Label Unequipped errored seconds

LSS_ES

Loss of Synch errored seconds

LOP_ES

Loss of Pointer errored seconds

J1TIM_ES

Path trace mismatch errored seconds

PAYL_C

Payload errors

PAYL_ES

Payload errored seconds

PAYL_ER

Payload error ratio

RDIPAY_ES

Path RDI (Payload) errored seconds

RDICON_ES

Path RDI (Connectivity) errored seconds

RDISRV_ES

Path RDI (Server) errored seconds

:SENSe:MEASure:PATH:WINDow:ALL

This query returns the values of all of the parameters of the :SENSe:MEASure:PATH:WINDow? query, as measured during the most recent N-second period. The parameters are returned in the order in which they are listed under :SENSe:MEASure:PATH:WINDow. Ratios are returned in NR3 format; other values are returned in NR1 format.

Syntax: :SENSe<slot>:MEASure:PATH:WINDow:ALL?

3-38

OTS9100 User Manual

Page 169
Image 169
Tektronix 071-0855-05 user manual SENSeMEASurePATHCUMUlativeALL, SENSeMEASurePATHWINDowALL