Specifications
A-12 OTS9100 User Manual
622 MHz Trigger Output
Connector: SMA
External Termination: 50, AC coupled
Voltage Level: 500 mVpp
Frequency: 622.08 MHz
Description: Signal provided as a scope trigger for viewing data eye diagrams. This sub-rate clock is
derived from the Line Clock.
External 155.52 MHz Clock Input
Connector: SMA
Internal Termination: 50, AC coupled
Voltage Level: 800 mVpp ± 200 mVpp
Frequency: 155.52 MHz ± 150ppm
Description: Provides a means to synchronize the transmit system to a user supplied reference.
Transmitter Data Output (Electrical)
Connector: SMA
External Termination: 50, DC coupled
Voltage Output LOW: 0.00V Vol -0.10V
Voltage Output HIGH: -0.45V Voh -0.60V
Description: Provides the 10 Gb/s data signal. Typically connected to TX DATA IN on the Optics
card.
10 GHz Clock Input
Connector: SMA
Internal Termination: 50, AC coupled
Voltage Level: 800 mVpp (nominal)
Frequency: 9.95328 GHz ± 150ppm
Description: Provides the Bit rate clock for the transmitter data output. This input is connected to
the 10 Ghz Clock OUT of the Clock Trigger card (OTS91C3).
10 GHz Trigger Output