Reference: Remote Commands ~ Command Description

:SENSe:MEASure:APSTime:THREshold

This command sets the threshold time for APS switch time measurement. If the measured switch time exceeds the threshold time, the test fails. The query form returns the current setting.

Syntax: :SENSe<slot>:MEASure:APSTime:THREshold? :SENSe<slot>:MEASure:APSTime:THREshold <NR1>

:SENSe:MEASure:APSTime:VALUe

This query returns, as a NR1 value, the APS switch time value measured by the most recently performed APS measurement. The units for the value can be specified as milliseconds, microseconds, or frames. If the unit specification is omitted, the unit defaults to milliseconds.

Syntax: :SENSe:MEASure:APSTime:VALUe? <Enum>

Parameters

Description

FRAMES

The current APS time value in frames

USEC

The current APS time value in microseconds

MSEC

The current APS time in milliseconds

NOTE: This command is only targeted for a receiver card. Unlike other cards, you cannot target the optical card directly by using the slot number of the optical card.

:SENSe:MEASure:HDLC:FRAMes

This query returns the value of the specified result parameter in NR1 format.

Syntax :SENSe<slot>:MEASure:HDLC:FRAMes? <Parameter>

Parameters

Description

GFCS

Count of HDLC frames received with good FCS

BFCS

Count of HDLC frames received with bad FCS

ABORted

Count of aborted HDLC frames

INValid

Count of invalid HDLC frames

MINSize

Count of HDLC frames received with minimum size violation

:SENSe:MEASure:HDLC:FRAMes:ALL

This query returns the values of all of the parameters of the SENSe :MEASure:HDLC:FRAMes? query. The parameters are returned in the order in which they are listed under :SENSe:MEASure:HDLC:FRAMes values are returned in NR1 format.

Syntax :SENSe<slot>:MEASure:HDLC:FRAMes:ALL?

OTS9100 User Manual

3-35

Page 166
Image 166