Reference: Remote Commands ~ Command Description

OTS9100 User Manual 3-17
:SENSe:ANALysis:G826A:MS:NEAR
This query returns the value of the specified Near-End Multiplexer Section parameter from G.826 analysis
of received data.
Syntax :SENSe<slot>:ANALysis:G826A:MS:NEAR? <Enum>
Parameters Description
ETIME Elapsed time
EB_C Errored blocks
EB_R Errored block ratio
BBE_C Background block errors
BBE_R Background block error ratio
EFS_C Error-free seconds
EFS_R Error-free seconds ratio
ES_C Errored seconds
ES_R Errored second ratio
SES_C Severely errored seconds
SES_R Severely errored second ratio
CSES_C Consecutive SES periods
UAS_C Unavailable seconds
UAS_R Una vailable seconds error ratio

:SENSe:ANALysis:G826A:MS:NEAR:ALL
This query returns the values of all of the Near-End Multiplexer S ection parameters from G.826 analysis
of received data. The parameters are returned in the order in which th ey are listed under
:SENSe:ANALysis:G826A:MS:NEAR.

Syntax :SENSe<slot>:ANALysis:G826A:MS:NEAR:ALL?

:SENSe:ANALysis:G826A:PATH:FAR
This query returns the value of the specified Far-End Path parameter f rom G.826 analysis of received
data. Ratios are returned as NR3 values, other parameters as NR1 values.
Syntax: :SENSe<slot>:ANALysis:G826A:PATH:FAR? <Enum >
Parameters Description
ETIME Elapsed time
EB_C Errored blocks
EB_R Errored block ratio
BBE_C Background block errors
BBE_R Background block error ratio
EFS_C Error-free seconds
EFS_R Error-free seconds ratio
ES_C Errored seconds
ES_R Errored second ratio
SES_C Severely errored seconds
SES_R Severely errored second ratio
CSES_C Consecutive SES periods
UAS_C Unavailable seconds
UAS_R Una vailable seconds error ratio