Reference: Remote Commands ~ Command Description

:SENSe:MEASure:LINE:WINDow

This query returns the value of the specified result parameter as measured during the most recent 'N' seconds. The duration 'N' of the measurement window is set by the :SENSE:MEASURE:WINDOW:SIZE command.

Syntax :SENSe<slot>:MEASure:LINE:WINDow? <Enum>

Parameters

Description

B2_C

B2 errors

B2_ES

B2 errored seconds

B2_ER

B2 error ratio

REI_C

REI errors

REI_ES

REI errored seconds

REI_ER

REI error ratio

AIS_ES

Loss-of-signal errored seconds

RDI_ES

Loss-of-frame errored seconds

:SENSeMEASure:LINE:WINDow:ALL

This query returns the values of all of the parameters of the :SENSE:MEASURE:LINE:WINDOW? query, as measured during the most recent N-second period. The parameters are returned in the order in which they are listed under :SENSE:MEASURE:LINE:WINDOW.

Syntax :SENSe<slot>:MEASure:LINE:WINDow:ALL?

:SENSe:MEASure:PATH:CUMUlative

This query returns the value of the specified result parameter for the most recent test. Ratios are returned in NR3 format; other values are returned in NR1 format.

Syntax: :SENSe<slot>:MEASure:PATH:CUMUlative? <Enum>

Parameters

Description

B3_C

B3 errors

B3_ES

B3 errored seconds

B3_ER

B3 error ratio

REI_C

Path REI errors

REI_ES

Path REI errored seconds

REI_ER

Path REI error ratio

AIS_ES

Path AIS errored seconds

RDI_ES

Path RDI errored seconds

PLM_ES

Path Label Mismatch errored seconds

UNEQ_ES

Path Label Unequipped errored seconds

LSS_ES

Loss of Synch errored seconds

LOP_ES

Loss of Pointer errored seconds

J1TIM_ES

Path trace mismatch errored seconds

PAYL_C

Payload errors

PAYL_ES

Payload errored seconds

PAYL_ER

Payload error ratio

RDIPAY_ES

Path RDI (Payload) errored seconds

RDICON_ES

Path RDI (Connectivity) errored seconds

RDISRV_ES

Path RDI (Server) errored seconds

OTS9100 User Manual

3-37

Page 168
Image 168
Tektronix 071-0855-05 user manual SENSeMEASureLINEWINDowALL, SENSeMEASurePATHCUMUlative