Reference: Remote Commands ~ Command Description

:SENSe:MEASure:HDLC:BYTes

This query returns the number of HDLC bytes received with good FCS.

Syntax :SENSe<slot>:MEASure:HDLC:BYTes?

:SENSe:MEASure:IP:PACKets

This query returns the value of the specified result parameter in NR1 format.

Syntax :SENSe<slot>:MEASure:IP:PACKets? <Parameter>

Parameters

Description

TOTal

Total count of IP bytes received

GOOD

Count IP bytes received with good checksum

BAD

Count of IP bytes received with bad checksum

FREE

Count of IP Packet received with no payload errors

PAYLoad

Count of IP Packet received with payload errors

:SENSe:MEASure:IP:PACKets:ALL

This query returns the values of all of the parameters of the SENSe :MEASure:IP:PACKets? query. The parameters are returned in the order in which they are listed under :SENSe:MEASure:IP:PACKets values are returned in NR1 format.

Syntax :SENSe<slot>:MEASure:IP:PACKets:ALL?

:SENSe:MEASure:LINE:CUMUlative

This query returns the value of the specified result parameter for the most recent test. Syntax :SENSe<slot>:MEASure:LINE:CUMUlative? <Enum>

Parameters

Description

B2_C

B2 errors

B2_ES

B2 errored seconds

B2_ER

B2 error ratio

REI_C

REI errors

REI_ES

REI errored seconds

REI_ER

REI error ratio

AIS_ES

AIS errored seconds

RDI_ES

RDI errored seconds

:SENSe:MEASure:LINE:CUMUlative:ALL

This query returns the values of all of the parameters of the :SENSE:MEASURE:LINE:CUMULATIVE? query. The parameters are returned in the order in which they are listed under

:SENSE:MEASURE:LINE:CUMULATIVE.

Syntax :SENSe<slot>:MEASure:LINE:CUMUlative:ALL?

3-36