Specifications
OTS9100 User Manual A-13
Connector: SMA
External Termination: 50, DC coupled
Voltage Level: 0.0 Vdc, 800 mVpp (nominal)
Frequency: 9.95238 GHz
Description: Provides a copy of the 10 GHz Clock OUT which may be used for a scope trigger.
RX Clock Input
Connector: SMA
Internal Termination: 50, AC coupled
Voltage Level: 800 mVpp (nominal)
Frequency: 155.52 MHz +/- 150 ppm
Description: Signal is used by the PLL to lock the transmitter data output to recovered clock. Used
for through mode or recovered timing when selected.
10 GHz Clock Output
Connector: SMA
External Termination: 50, AC coupled
Voltage Output: 2.19 +/- 0.41 Vpp, 0.0 Vdc (10.6dbm +/- 1.6db)
Frequency: 9.95328 GHz +/- 150 ppm
Description: Bit rate clock for transmitter data output. This output is connected to the 10GHz Clock
IN of the Transmit card.