Tektronix 071-0855-05 user manual SOURceTRIGgerMODE, STATusPRESet, SYSTemCOMMunicateGPIBPRIMary

Models: 071-0855-05

1 253
Download 253 pages 20.53 Kb
Page 196
Image 196

Reference: Remote Commands ~ Command Description

:SOURce:TRIGger:MODE

This command sets the condition that will produce a trigger output from the OTS-9000 transmitter. The query form returns the current setting.

Syntax :SOURce<slot>:TRIGger:MODE? :SOURce<slot>:TRIGger:MODE <Enum>

Parameters

Description

OFF

The trigger output is disabled

ANOMaly

A trigger occurs when an anomaly is generated

DEFEct

A trigger occurs when a defect is generated

AD

A trigger occurs when an anomaly or defect is generated

:STATus:PRESet

This command initializes the Interface Status subsystem to a defined initial state.

Syntax :SYSTem:COMMunicate:GPIB:PRIMary? :SYSTem:COMMunicate:GPIB:PRIMary <Enum> <NR1>

Parameters

Description

NONE

The GPIB port is disabled

:SYSTem:COMMunicate:GPIB:PRIMary

This command sets the primary address for the GPIB remote control port. A value of NONE disables the GPIB port. The query form returns the current setting.

Syntax :SYSTem:COMMunicate:GPIB:PRIMary? :SYSTem:COMMunicate:GPIB:PRIMary <Enum> <NR1>

Parameters

Description

NONE

The GPIB port is disabled

:SYSTem:COMMunicate:GPIB:SECOndary

This command sets the secondary address for the GPIB port. A value of NONE disables secondary addressing. The query form returns the current setting.

Syntax :SYSTem:COMMunicate:GPIB:SECOndary? :SYSTem:COMMunicate:GPIB:SECOndary <Enum> <NR1>

Parameters

Description

NONE

Secondary GPIB addressing is disabled

OTS9100 User Manual

3-65

Page 196
Image 196
Tektronix 071-0855-05 SOURceTRIGgerMODE, STATusPRESet, SYSTemCOMMunicateGPIBPRIMary, SYSTemCOMMunicateGPIBSECOndary