Operating Basics: User Interface
OTS9100 User Manual 2-57
RS Trace (Section Trace) (J0)
The Section Trace (J0) provides the current values of the J0 multi-byte trace. The 16-byte J0
Trace receives 15 bytes ending with a CRC. The 64-byte J0 Trace receives 62 bytes with CR LF.
The Expected and Received values are both displayed, providing an easy visual comparison of
the J0 Trace. The length of the Trace is also provided as both expected and received values.
S1 Synchronization Status
S1 Synchronization Status displays the S1 byte values. The S1 byte values are decoded and
displayed in ASCII format. To edit the S1 byte, go to the Overhead section of the Transmitter
setup and enter the desired hexadecimal value.
The S1 byte display is only active when the overhead channel is set to 1.