Reference: Remote Commands ~ Command Description

:SOURce:DATA:IP:STReam:INDEX

This query form returns the transmitter sub stream index.

Syntax :SOURce<slot>:DATA:IP:STReam:INDEX?

:SOURce:DATA:IP:TRAFfic

This command sets the transmitter IP traffic state. The query form returns the IP traffic state.

Syntax :SOURce<slot>:DATA:IP:TRAFfic? :SOURce<slot>:DATA:IP:TRAFfic <Boolean>

:SOURce:DATA:POS:SCRambling

This command enables or disables the packet over SONET scrambling. The query form returns the current setting.

Syntax :SOURce<slot>:DATA:POS:SCRambling? :SOURce<slot>:DATA:POS:SCRambling <Boolean>

:SOURce:DATA:OVERhead:PASSthru

This command controls the source of transmitted overhead data in Through Mode. The first parameter specifies an overhead data field; the second selects whether that field's data comes from the received signal (ON) or is generated by the OTS transmitter (OFF). The query form returns the current setting for the specified field.

Syntax :SOURce<slot>:DATA:OVERhead:PASSthru? <Enum> :SOURce<slot>:DATA:OVERhead:PASSthru <Enum> ,<Boolean>

Parameters

Description

APS

K1 and K2 (APS) bytes (bit value 16 in ...:ALL command)

DCC_S

D1 through D3 (Section DCC) bytes (bit value 8)

DCC_L

D4 through D12 (Line DCC) bytes (bit value 32)

E1A

E1 byte (bit value 2)

E2A

E2 byte (bit value 512)

F1A

F1 byte (bit value 4)

J0A

J0 (Section trace) byte (bit value 1)

M1A

M1 byte (bit value 128)

S1A

S1 byte (bit value 64)

Z2A

Z2 byte (bit value 256)

OTS9100 User Manual