Reference: Remote Commands ~ Command Description

:SOURce:INSErt:DEFEct:MODE

This command specifies how defects are inserted. The query form returns the current setting.

Syntax :SOURce<slot>:INSErt:DEFEct:MODE? :SOURce<slot>:INSErt:DEFEct:MODE <Enum>

Parameters

Description

NONE

Defect insertion is disabled

BURSt

A defect condition is asserted for a programmed time

CONTinuous

A defect condition is asserted continously

:SOURce:INSErt:DEFEct:STATe

This query returns the current state of defect insertion.

Syntax :SOURce<slot>:INSErt:DEFEct:STATe?

Parameters

INACT

SING_INACT SING_DWELL BRST_INACT BRST_ACT BRST_DWELL CONT_INACT CONT_ACT CONT_DWELL

Description

Defect/anomaly insertion is inactive One-time defect/anomaly insertion is inactive One-time defect/anomaly insertion is active Burst defect/anomaly insertion is inactive

Burst defect/anomaly insertion is active, between bursts Burst defect/anomaly insertion is active

Continuous defect/anomaly insertion is inactive Continuous defect/anomaly insertion is inactive Continuous defect/anomaly insertion is active

:SOURce:INSErt:DEFEct:TIME

This command sets the duration of timed defect insertion in the units appropriate to the selected defect. The query form returns the current value.

Syntax :SOURce<slot>:INSErt:DEFEct:TIME? :SOURce<slot>:INSErt:DEFEct:TIME <NR1>

3-60