Tektronix 071-0855-05 Module Interconnect Specifications, Signal Name Tx Data Out / Tx Data

Models: 071-0855-05

1 253
Download 253 pages 20.53 Kb
Page 228
Image 228

Specifications

Module Interconnect Specifications

Signal Name: Tx Data Out / Tx Data In

Connector: SMA

Voltage Level: 0.5 Vpp (typical)

Description: Electrical data signal. Connect Tx DATA OUT (Transmit card) to Tx DATA IN (Optics card) with Tektronix supplied cable accessories

Signal Name: Rx Data Out / Rx Data In

Connector: SMA

Voltage Level: 0.70 Vpp (typical)

Description: Electrical data signal. Connect Rx DATA OUT (Optics card) to Rx DATA IN (Receive card) with Tektronix supplied cable accessories (SMA-SMA coax and DC-Block).

Signal Name: Rx Data Out / 10GHz/s Data In

Connector: SMA

Voltage Level: 0.70 Vpp (typical)

Description: Electrical data signal. Connect Rx DATA OUT (Optics card) to 10GHz/s DATA IN (Jitter Clock Receive Card) with Tektronix supplied cable accessories (SMA-SMA coax). Otherwise, terminate Rx DATA OUT with 50Ω.

Signal Name: Rx Clock Out / Rx Clock In

Connector: SMA

Voltage Level: 0.8Vpp (typical)

Description: Clock signal. Connect Rx CLK OUT (Receive card) to Rx CLK IN (Sync card) with Tektronix supplied cable accessory (SMA-SMA coax).