Reference: Remote Commands ~ Command Description

:SENSe:ANALysis:G826A:RS

This query returns the value of the specified Regenerator Section parameter from G.826 analysis of received data.

Syntax :SENSe<slot>:ANALysis:G826A:RS? <Enum>

Parameter

Description

ETIME

Elapsed time

EB_C

Errored blocks

EB_R

Errored block ratio

BBE_C

Background block errors

BBE_R

Background block error ratio

ES_C

Errored seconds

ES_R

Errored second ratio

SES_C

Severely errored seconds

SES_R

Severely errored second ratio

CSES_C

Consecutive SES periods

UAS_C

Unavailable seconds

UAS_R

Unavailable seconds error ratio

:SENSe:ANALysis:G826A:RS:ALL

This query returns the values of all of the Regenerator Section parameters from G.826 analysis of received data. The parameters are returned in the order in which they are listed under :SENSe:ANALysis:G826A:RS.

Syntax :SENSe<slot>:ANALysis:G826A:RS:ALL?

:SENSe:ANALysis:GR253A:LINE:FAR

This query returns the value of the specified Far-End Line parameter from GR-253 analysis of received data.

Syntax :SENSe<slot>:ANALysis:GR253A:LINE:FAR? <Enum>

Parameters

CV_C

CV_R

BBE_C

BBE_R

ES_C

ES_R

SES_C

SES_R

ESA_C

ESA_R

ESB_C

ESB_R

CSES_C

UAS_C

UAS_R

Description

CV Count

CV Count Ratio Background block errors Background block error ratio Errored seconds

Errored second ratio Severely errored seconds Severely errored second ratio Errored seconds type A Errored second type A ratio Errored seconds type B Errored second type B ratio Consecutive SES periods Unavailable seconds Unavailable seconds error ratio

OTS9100 User Manual

3-19

Page 150
Image 150
Tektronix 071-0855-05 user manual SENSeANALysisG826ARSALL, SENSeANALysisGR253ALINEFAR