Reference: Remote Commands ~ Command Description

:SENSe:ANALysis:GR253A:SECTion

This query returns the value of the specified Section parameter from GR-253 analysis of received data. Syntax :SENSe<slot>:ANALysis:GR253A:SECTion? <Enum>

Parameters

Description

CV_C

CV Count

CV_R

CV Count ratio

BBE_C

Background block errors

BBE_R

Background block error ratio

ES_C

Errored seconds

ES_R

Errored second ratio

SES_C

Severely errored seconds

SES_R

Severely errored second ratio

ESA_C

Errored seconds type A

ESA_R

Errored second type A ratio

ESB_C

Errored seconds type B

ESB_R

Errored second type B ratio

CSES_C

Consecutive SES periods

UAS_C

Unavailable seconds

UAS_R

Unavailable seconds error ratio

SEFS_C

Severely errored framing seconds

SEFS_R

Severely errored framing second ratio

:SENSe:ANALysis:GR253A:SECTion:ALL

This query returns the values of all of the Section parameters from GR-253 analysis of received data. The parameters are returned in the order in which they are listed under :SENSe:ANALysis:GR253A:SECTion.

Syntax :SENSe<slot>:ANALysis:GR253A:SECTion:ALL?

:SENSe:ANALysis:PATH:HPPLM

This command enables or disables the inclusion of Path Label Mismatch errors in the analysis of received signals. The query form returns the current setting.

Syntax: :SENSe<slot>:ANALysis:PATH:HPPLM? :SENSe<slot>:ANALysis:PATH:HPPLM <Boolean>

OTS9100 User Manual

3-23

Page 154
Image 154
Tektronix 071-0855-05 user manual SENSeANALysisGR253ASECTionALL, SENSeANALysisPATHHPPLM