Reference: Remote Commands ~ Command Description

:SENSe:ANALysis:PATH:TRACe:TIM

This command enables or disables the inclusion of path Trace Identifier Mismatch errors in the analysis of received signals. The query form returns the current setting.

Syntax: :SENSe<slot>:ANALysis:PATH:TRACe:TIM? :SENSe<slot>:ANALysis:PATH:TRACe:TIM <Boolean>

:SENSe:ANALysis:SECTion:TRACe:EXPEcted

This command sets the data sequence length and data byte values against which the receiver compares the received signal for Trace Identifier Mismatch measurements. The data bytes are formatted as a standard IEEE-488 data block. The query form returns the current settings of these parameters.

Syntax :SENSe<slot>:ANALysis:SECTion:TRACe:EXPEcted? :SENSe<slot>:ANALysis:SECTion:TRACe:EXPEcted <Enum> ,<Block>

Parameters

Description

L1B

Constant 8-bit data

L16B

A repeating sequence of 16 bytes, 0-filled with CRC

L16FREE

A repeating sequence of 16 bytes, arbitrary format

L64B

A repeating sequence of 64 bytes, space-filled with CR/LF

L64FREE

A repeating sequence of 64 bytes, arbitrary format

:SENSe:ANALysis:SECTion:TRACe:EXPEcted:TYPE

This command sets the data sequence length used by the receiver for Trace Identifier Mismatch measurements. This parameter may also be set by the :SENSe:ANALysis:SECTion:TRACe:EXPEcted command. The query form returns the current setting of this parameter.

Syntax :SENSe<slot>:ANALysis:SECTion:TRACe:EXPEcted:TYPE? :SENSe<slot>:ANALysis:SECTion:TRACe:EXPEcted:TYPE <Enum>

Parameters

Description

L1B

Constant 8-bit data

L16B

A repeating sequence of 16 bytes, 0-filled with CRC

L16FREE

A repeating sequence of 16 bytes, arbitrary format

L64B

A repeating sequence of 64 bytes, space-filled with CR/LF

L64FREE

A repeating sequence of 64 bytes, arbitrary format