Tektronix 071-0855-05 user manual SENSeANALysisGR253ALINEFARALL, SENSeANALysisGR253ALINENEAR

Models: 071-0855-05

1 253
Download 253 pages 20.53 Kb
Page 151
Image 151

Reference: Remote Commands ~ Command Description

:SENSe:ANALysis:GR253A:LINE:FAR:ALL

This query returns the values of all of the Far-End Line parameters from GR-253 analysis of received data. The parameters are returned in the order in which they are listed under :SENSe:ANALysis:GR253A:LINE:FAR.

Syntax :SENSe<slot>:ANALysis:GR253A:LINE:FAR:ALL?

:SENSe:ANALysis:GR253A:LINE:NEAR

This query returns the value of the specified Near-End Line parameter from GR-253 analysis of received data.

Syntax :SENSe<slot>:ANALysis:GR253A:LINE:NEAR? <Enum>

Parameters

CV_C

CV_R

BBE_C

BBE_R

ES_C

ES_R

SES_C

SES_R

ESA_C

ESA_R

ESB_C

ESB_R

CSES_C

UAS_C

UAS_R

Description

CV Count

CV Count ratio Background block errors Background block error ratio Errored seconds

Errored second ratio Severely errored seconds Severely errored second ratio Errored seconds type A Errored second type A ratio Errored seconds type B Errored second type B ratio Consecutive SES periods Unavailable seconds Unavailable seconds error ratio

:SENSe:ANALysis:GR253A:LINE:NEAR:ALL

This query returns the values of all of the Near-End Line parameters from GR-253 analysis of received data. The parameters are returned in the order in which they are listed under :SENSe:ANALysis:GR253A:LINE:NEAR.

Syntax : SENSe<slot>:ANALysis:GR253A:LINE:NEAR:ALL?

3-20

OTS9100 User Manual

Page 151
Image 151
Tektronix 071-0855-05 user manual SENSeANALysisGR253ALINEFARALL, SENSeANALysisGR253ALINENEARALL