Reference: Remote Commands ~ Command Description

:SENSe:DATA:PAYLoad:PATTern:UDATA

This command selects the fixed test pattern for the received signal. The query form returns the current setting.

Syntax: :SENSe<slot>:DATA:PAYLoad:PATTern:UDATA? :SENSe<slot>:DATA:PAYLoad:PATTern:UDATA <NR1>

:SENSe:DATA:POH:ALL

This query returns a block of data representing the Path Overhead data from an STS-1 in the received signal. There are 9 bytes in the block returned. For SONET, these bytes are J1 B3 C2 G1 F2 H4 Z3 Z4 Z5; for SDH, these bytes are J1 B3 C2 G1 F2 H4 F3 K3 N1.

Syntax: :SENSe<slot>:DATA:POH:ALL? [<NR1>]

:SENSe:DATA:POH:BYTE

This query returns a single byte of data from the Path Overhead data for the selected active channel in the received signal. The numeric parameter, with range 1 to 9, specifies the byte in the order listed under :SENSe:DATA:POH:ALL.

Syntax: :SENSe<slot>:DATA:POH:BYTE? <NR1>

:SENSe:DATA:POH:BYTE:C2A

This query returns the Path Label (C2) byte from the selected active channel in the received signal. Syntax: :SENSe<slot>:DATA:POH:BYTE:C2A?

:SENSe:DATA:POS:SCRambling

This command enables or disables the packet over sonnet scrambling. The query form returns the current setting. <Slot> is an optional number that specifies the module slot containing the device that is the target of the command; if omitted, it defaults to the lowest-numbered slot containing an applicable device.

Syntax :SENSe<slot>:DATA:POS:SCRambling? :SENSe<slot>:DATA:POS:SCRambling <Boolean>

3-30

OTS9100 User Manual

Page 161
Image 161
Tektronix 071-0855-05 SENSeDATAPAYLoadPATTernUDATA, SENSeDATAPOHALL, SENSeDATAPOHBYTEC2A, SENSeDATAPOSSCRambling