Reference: Remote Commands ~ Command Description

:SOURce:DATA:TOH:STS1A:DEFAult

This command sets all bytes in the generated STS-1 #1 Transport Overhead data to their default values. Syntax :SOURce<slot>:DATA:TOH:STS1A:DEFAult

:SOURce:INSErt:ANOMaly:MODE

This command specifies how anomalies are inserted. The query form returns the current setting.

Syntax :SOURce<slot>:INSErt:ANOMaly:MODE? :SOURce<slot>:INSErt:ANOMaly:MODE <Enum>

Parameter

Description

NONE

Anomaly insertion is disabled

SINGle

A single anomaly is inserted

BURSt

A burst of anomalies is inserted

:SOURce:INSErt:ANOMaly:RATE

This command sets the rate at which continuously-generated anomalies are inserted. The query form returns the current value.

Syntax :SOURce<slot>:INSErt:ANOMaly:RATE? :SOURce<slot>:INSErt:ANOMaly:RATE <NR3>

:SOURce:INSErt:ANOMaly:RATE:RANGe

This query returns the minimum and maximum rate values for the specified anomaly type. Syntax :SOURce<slot>:INSErt:ANOMaly:RATE:RANGe? <Enum>

Parameters

Description

NONE

No anomaly is selected

B1BIP

B1 parity errors

B2BIP

B2 parity errors

B3BIP

B3 parity errors

REI

Line REI errors

REI_P

Path REI errors

PATTern

Pattern bit errors

RANDom

Errors in randomly-selected framing, overhead, and payload bits

BIT_SPE

Errors in randomly-selected SPE bits (SONET mode only)

BIT_VC

Errors in randomly-selected VC bits (SDH mode only)