TOA Electronics C-DR091 CU Series, C-DR161 CU Series Control I/O Terminal Connections

Models: C-DR161 CU Series C-DR091 CU Series

1 130
Download 130 pages 36.17 Kb
Page 25
Image 25

10.3. Control I/O Terminal Connections

The control input and output terminals include: priority recording terminal, camera control terminal, remote controller input/output terminals, control output terminal, and time synchronization input/output terminals. (Refer to p. 14; Nomenclature and Functions.)

PRIORITY

NC

+

CAMERA

 

RM IN-B

RM OUT-B

-

IN G

 

G - +

G

-

+ G

 

 

 

CONTROL OUT

 

 

 

TIME SYNC

 

1

G

2

G

3

G

4

G

IN

G OUT

G

A

B

Terminal name A

Name

PRIORITY IN

Priority Recording Input

PRIORITY G

Priority Recording Ground

NC

Not connected

CAMERA +

Camera Control (RS-485) +

CAMERA G

Camera Control (RS-485) Ground

CAMERA -

Camera Control (RS-485) -

RM IN-B +

Remote Control Input B + (RS-485)

RM IN-B G

Remote Control Input B Ground

RM IN-B -

Remote Control Input B - (RS-485)

RM OUT-B +

Remote Control Output B + (RS-485)

RM OUT-B G

Remote Control Output B Ground

RM OUT-B -

Remote Control Output B - (RS-485)

Terminal name B

Name

CONTROL OUT 1

Control Output 1

CONTROL OUT G

Control Output Ground

CONTROL OUT 2

Control Output 2

CONTROL OUT G

Control Output Ground

CONTROL OUT 3

Control Output 3

CONTROL OUT G

Control Output Ground

CONTROL OUT 4

Control Output 4

CONTROL OUT G

Control Output Ground

TIME SYNC IN

Date/Time Adjustment Input

TIME SYNC G

Date/Time Adjustment Input Ground

TIME SYNC OUT

Date/Time Adjustment Output

TIME SYNC G

Date/Time Adjustment Output Ground

Note

Ensure that the cable is securely locked into the terminal after connection. (Refer to p. 24; Alarm input terminal connections.)

10.3.1. Time synchronization input/output terminal connections

Two different methods are available to synchronize the time, one using both master and slave units, the other using NTP. (Refer to p. 100; Date/time setting.)

Note

When synchronizing a single-channel Digital Video Recorder, set the synchronization interval to “5 seconds.” (Refer to p. 100; Date/time setting.)

Input Output

Master

Input Output

Slave 1

Input Output

Slave 2

Input Output

Slave 7

To synchronize the times of slave units with the time of the master unit, connect the slave units to the master unit in a series via their input and output terminals. In other words, connect the input of slave number 1 to the master unit’s output and the input of slave number 2 to slave number 1’s output, and so on.

10.4. 10BASE-T/100BASE-TX Terminal Connections

Use this terminal to remotely monitor or control cameras connected to the Digital Video Recorder, or search or play back their recorded images on a PC web browser. When connecting a PC directly to the Digital Video Recorder, use a network crossover cable. Use the straight-through cable for connection between them via a switching hub.

25

Page 25
Image 25
TOA Electronics C-DR091 CU Series Control I/O Terminal Connections, BASE-T/100BASE-TX Terminal Connections