TOA Electronics C-DR161 CU Series Alarm Event Recording Setting, Total rec rate

Models: C-DR161 CU Series C-DR091 CU Series

1 130
Download 130 pages 36.17 Kb
Page 82
Image 82

[ Alarm Event Recording Setting ]

Preset camera images are automatically recorded when an alarm event occurs. Recording “Enable” (ON) or “Disable” (OFF), recording rate, picture quality and event settings can be performed for each camera. The recording rate for cameras other than alarm event-activated cameras and the total recording rate are both displayed near the bottom of the screen.

A L A R M E V E N T R E C S E T T I N G A

 

 

R E C

R E C R A T E Q U A L I T Y

E V E N T

C A M 1

O

 

N

 

8 I P S

4

 

C A M 2

O N

2 I P S

3 ( M I D )

 

C A M 3

O N

1 5 I P S

2

 

C A M 4

O N

1 5 I P S

1 ( H I G H )

 

C A M 5

O F F

1 / 6 0 I P S

2

 

C A M 6

O F F

-

-

 

C A M 7

O F F

-

-

 

C A M 8

O F F

-

-

 

C A M 9

O F F

-

-

 

C A M 1 0

O F F

-

-

 

C A M 1 1

O F F

-

-

 

C A M 1 2

O F F

-

-

 

C A M 1 3

O F F

-

-

 

C A M 1 4

O F F

-

-

 

C A M 1 5

O F F

-

-

 

C A M 1 6

O F F

-

-

 

R E C R A T E E X C E P T E V E N T C A M

4 I P S

T O T A L R E C R A T E

3 9 . 3 7 5 0 I P S

Total rec rate:

When Alarm Event Recording mode is set to "Sequence" :

The total recording rate for each of the cameras is displayed. If the recording rate for one camera is a smaller value than "Recording Rate Other Than Event Cameras," then its recording rate is regarded as the "Recording Rate Other Than Event Cameras” when calculating.

When Alarm Event Recording mode is set to "Last" :

Displays the total of the largest recording rate of one camera out of those to be recorded and the sum of "Recording Rate Other Than Event Cameras" of other cameras (other cameras' recording rate is all regarded as the "Recording Rate Other Than Event Cameras" even if each of their rates is smaller than that).

Note

If the disk mode is set to "Normal," then set Total Recording Rate to 120 IPS or less. If the disk mode is set to "Mirror," then set Total Recording Rate to 60 IPS or less. Settings above these are not possible.

Item

Selection

Description

 

 

 

 

 

 

 

REC

ON / OFF

ON: Recording is performed during Alarm event recording *1

 

 

 

 

 

 

OFF: Recording is not performed during Alarm event recording *1

 

 

 

 

 

 

 

REC RATE

60 IPS / 30 IPS / 15 IPS /

Sets the recording rate during recording. *1 *2

 

8 IPS / 4 IPS / 2 IPS / 1 IPS /

 

 

 

 

 

 

 

 

 

1/2 IPS / 1/3 IPS / 1/5 IPS /

 

 

1/10 IPS / 1/20 IPS / 1/30 IPS

 

 

/ 1/60 IPS

 

 

 

 

 

 

 

 

QUALITY

1 HIGH

Sets the picture quality level for the recording *1

 

2

 

 

 

1: 64 KB (High picture quality)

 

3 MID

 

2: 40 KB

 

4

 

 

 

 

 

 

 

3: 32 KB

 

5 LOW

 

4: 24 KB

 

 

 

 

 

 

 

 

 

 

 

 

5: 16 KB (Low picture quality)

 

 

 

 

 

 

 

EVENT

 

 

 

 

 

For setting, refer to p. 83; Event setting.

 

 

 

 

 

 

 

REC RATE

4 IPS / 2 IPS / 1 IPS / 1/2 IPS

Set the recording rate for recording “Disable” cameras during

EXCEPT EVENT

/ 1/3 IPS / 1/5 IPS / 1/10 IPS /

alarm event recording.

CAM

1/20 IPS / 1/30 IPS / 1/60 IPS

 

 

/ INVALID

 

 

 

 

 

 

 

 

Note: Underlined settings represent factory-preset settings. *1 Can be set for each camera.

*2 For recording rate, refer to p. 44; Recording Rate and p. 116; Recording timetable.