27.3. Security Setting

Access to the Digital Video Recorder’s operations and settings can be restricted using different security levels. It is also possible to control security level settings using the Remote Controller (RS-485 control) or a PC (RS-232C control). (Refer to p. 60; About security setting.)

S E C U R I T Y S E T T I N G

 

 

 

O P E R A T I O N

P A S S W O R D

U S B K E Y

L E V E L 1

V A L I D

( V A L I D )

L E V E L 2

I N V A L I D

(

I N V A L

I D )

L E V E L 3

I N V A L I D

(

I N V A L

I D )

U S B K E Y L E V E L

L E V E L 1

P R I O R I T Y R E C

I N V A L I D

O P E R A T I O N L E V E L 3

 

R E M O T E

A C C E S S L I M I T

O F F

L O G O U T

I N T E R V A L

1 0 M I N U T E

Item

 

Selection

Description

 

 

 

 

 

 

 

 

 

OPERATION

 

PASS

VALID

A password can be set to require login to each operation level.

LEVEL1-3

 

(6-digit number)

For an explanation of operating levels and their relationship to login and

 

WORD

 

 

 

/ INVALID

logout procedures, see page 60, About Security Setting.

 

 

 

 

 

 

 

USB

(VALID / INVALID)

Displays the content set for the USB key level.

 

 

KEY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Inserting a registered USB key in a key lock terminal allows settings to be

USB KEY LEVEL

LEVEL 1 /

 

 

 

LEVEL 2 /

changed. (Refer to p. 62; Security settings Using a USB Key.)

 

 

 

LEVEL 3 /

LEVEL 1: Select in order to log in to operation level 1.

 

 

 

INVALID

LEVEL 2: Select in order to log in to operation levels 1 and 2.

 

 

 

 

 

 

 

 

LEVEL 3: Select in order to log in to operation levels 1, 2, and 3.

 

 

 

 

 

 

 

 

INVALID: USB key security not used.

 

 

 

 

 

 

 

 

PRIORITY REC

VALID /

VALID: Possible to operate the Priority Recording key at operation level 3.*1

OPERATION

 

INVALID

INVALID: Not possible to operate the Priority Recording key at operation

LEVEL 3

 

 

 

 

 

 

level 3.*1

 

 

 

 

 

 

 

 

REMOTE ACCESS

ON / OFF

Restrict remote operation via remote controller or RS-232C.

LIMIT

 

 

 

 

 

 

ON: Restricts access at the level set by the Digital Video Recorder.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFF: Allows access at operation level 1 (full access).

 

 

 

 

 

 

 

 

 

LOGOUT

 

INVALID /

Set the length of time after which automatic logout will occur after no

INTERVAL

 

1 MINUTE /

operation has been conducted after a password login.

 

 

 

5 MINUTE /

INVALID: No automatic logout.

 

 

 

10 MINUTE /

1-60 MINUTE: Logout will occur after the specified amount of time.

 

 

 

30 MINUTE /

 

 

 

 

60 MINUTE

 

 

 

 

 

 

 

 

 

 

Note: Underlined settings represent factory-preset settings.

*1 It is not possible to restrict recording started from a Priority recording terminal.